Presettings
Operating instructions GLP
3 -- 69
6.562.98.5.01.18
3.5.4 Weight classes/statistics (only with terminal GT--CT)
3.5.4.1 Selection criteria
From program version 9.00 are available several small input tools for inserting va-
lues in the large weight class table, so you can choose your Selection criteria
according to the application. The values inserted are automatically inserted at the
corresponding position in the large weight class table. The large weight class ta-
ble may be always called up directly, values may be inserted or changed (see on
page 3 -- 87).
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] 2
Processing Wgt class
statistics
Selection
criteria
-- Call up the selection menu.
Selection criteria
Ja
Unknown
Cancel
OK
Weight determination
Checking contents
Sliding contents control
Weight classification
FPV Europe
USA -- non USDA standardized
Free selection
see page 3 -- 71
see page 3 -- 72
see page 3 -- 73
see page 3 -- 74
see page 3 -- 75
see page 3 -- 76
see page 3 -- 77
see page 3 -- 78
see page 3 -- 79
USA -- USDA standardized
USA -- USDA only liquid materials
or [ ] -- Select corresponding selection criteria.
OK
or [ENTER -- Acknowledge respective selection.
Cancel
-- Press softkey, if you want to exit the selection menu.
Description of selection criteria
Weight determination:
Determination/printout of all weighed package weights.
With statistics: Statistical evaluation of all packages, but no selections were car-
ried out for statistical reasons. (Statistic: e.g. mean value, lightest
and heaviest package, deviation from nominal weight ec.)
With divider: A divider can be assigned to all non defective packages. In case
e.g. a non--defective package is identified by the metal detector, it
is not deviated by the divider.
Checking contents:
Control of all packages, if package weight is in preset range.
With statistics: Statistical evaluation for all packages in the preset range, but no
selections were carried out for statistical reasons.
With divider: iEach category, the underweight, overweight or good--weight pak-
kages can be assigned a divider.