EasyManua.ls Logo

Bizerba GLP 80 - Page 208

Bizerba GLP 80
394 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Presettings
Operating instructions GLP
3 -- 70
6.562.98.5.01.18
Sliding contents control:
Completeness check with constant package weight (e.g. certain amount/number
of screws in a carton) and varying weight of the packaging. Example: A slow gro-
wing weight of the package carton due to air humidity can be compensated by
comparing nominal weight and mean value of the last x packages. So content
control is insensitive to external influences as humidity.
Weight classification:
The number of weight ranges offered (weight class columns) corrisponds to the
number of weight class columns preset in mode 5 (max. 80).
With divider: Each weight range can be assigned a divider, so the further proces-
sing can be controlled according to the package weight.
FPV Europe:
Control and selection of the packages according to the prepack regulations
(FPV).
with divider: Each category, the underweight, overweight or those packages with
the correct weight can be assigned a divider.
USA -- Non USDA standardized: Valid for all non--meat and poultry products
Tolerance limit TU1 and TOmax are calculated and displayed according to the
guidelines of the “Handbook 133”. Accepted are all packages that corrispond with
their statistical mean value to the nominal value preset or that exceed it. There
is only a lower tolerance limit TU1.
With divider: Each category, the underweight, overweight or those packages with
correct weight can be assigned a divider.
USA -- USDA
standardized
: Valid for all meat and poultry products
The tolerance limits TU1 and TOmax are calculated and displayed according to
the guidelines of the “Handbook 133”. Accepted are all packages that corrispond
with their statistical mean value to the nominal value preset or that exceed it.
There is only a lower tolerance limit TU1.
With divider: Each category, the underweight, overweight or those packages with
correct weight can be assigned a divider.
USA -- USDA only liguid materials: Valid for all non meat or poultry products
in liquid form, e.g. for baby food.
The tolerance limits TU1 and TOmax are calculated and displayed according to
the guidelines of the “Handbook 133”. Accepted are all packages that corrispond
with their statistical mean value to the nominal value preset or that exceed it.
There is only a lower tolerance limit TU1.
With divider: Each category, the underweight, overweight or those packages with
correct weight can be assigned a divider.
Free selection
Control and selection of the packages according to the preset upper and lower
tolerance limit. The mean value of the packages must not be under the preset
nominal weight!
With divider: Each category, the underweight, overweight or those packages with
correct weight can be assigned a divider.