Presettings
Operating instructions GLP
3 -- 71
6.562.98.5.01.18
3.5.4.2 Package selection
Weight determination
If Weight determination has been selected (see page 3 -- 69), presettings for
Weight determination can be entered after calling up Package selection.
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] 2
Processing Wgt class
statistics
Package
selection
-- Call up the selection menu.
Weight determination
Value
Nominal weight
Divider
Statistics
200 g
on
Package ejector
Display fixed weight
from PLU
if nominal weight
equal zero
Nominal weight:
xxxx [ENTER] -- Enter respective nominal weight and acknowledge.
Divider:
No presetting necessary with GLP !
Statistics:
If Statistics on is preset, a statistical evaluation for all packages is carried out,
but no selections are done for statistical reasons.
or [ ] -- Select option Statistics”.
or [TOGGLE] -- Set statistical function to on
or off”.
Store presettings: see page 3 -- 100