Presettings
Operating instructions GLP
3 -- 94
6.562.98.5.01.18
with free limits:
The lower and upper limits, between which packages are accepted, may be ent-
ered in the homonymous input fields depending on the weight class. If the nominal
weight is entered, all packages are accepted that are equal or larger than the stati-
stical mean value of the nominal weight preset. If no lower or upper limit is preset,
the weight ranges of the respective weight class column are valid.
without mean value criteria:
Accepted are all packages between the preset range of lower and upper limit. No
mean value is calculated and consequently no packages are ejected that are
lighter than the mean value. If no lower or upper limit is preset, the weight ranges
of the respective weight class column are valid.
self--adapting mean value:
A mean value is calculated for the last n packages (n = presettable package num-
ber). If this mean value deviates from the preset nominal weight, the nominal weight
is set to this new mean value and the upper and lower limit are modified accordingly
then. Thus, sliding weight changes may be compensated e.g. package.
Information on all statistics cards:
If nominal weight zero is preset, the fixed weight of the relevant PLU or the fixed
weight entered in mode 1 or 2 is used as a nominal weight. Thus, different nominal
weights may be controlled and statistically evaluated with one weight class table.
Presetting the Factor To (1..30)
For the ”to FPV Germany” statistic type, if the share of the accepted packages
is increased over the nominal weight Qn, then a larger factor can be entered
here. After the entry, the new upper limit TOmax is displayed.
TOmax = upper tolerance limit, standard presetting = 3, max. presetting = 30.
or [ ] -- Select the table field ”Factor To (1...30)”
or [SELECT] -- Activate the table field ”Factor To (1...30)”
xx [ENTER] -- Enter a new factor and acknowledge, e. g. 10.
TOmax = upper tolerance limit, standard presetting = 3, max. presetting = 30.
3
TO
Qn
0 kg
6 kg
TU2 TU1
200 g
182 g 191 g
TU1TU2
200
Qn
191182
236227
TO2
209
245 254
470
479
263
TO1
..
..
TO
max. 479 g
218 g
218
To
1
To
2
To
3
To
4
To
5
To
6
To
29
To
30
To
0
Statistics display
Table
209
218
Range of accepted packages depending
on the To factor (1..30) preset
Range stipulated
by the prepack--
aging regulations
(FPV)
TO range which can be
changed in steps via the To
factor (1...30)
Not variable
Variable via the To factor (1..30)
with a factor of To=3, TO = 236 g
with a factor of To=30, TO = 479 g