Presettings
Operating instructions GLP
3 -- 95
6.562.98.5.01.18
Enter lower limit
The minimum weight of the packages can be preset here. Packages below the
minimum weight are not accepted.
or [ ] -- Select the input field ”Min. level”.
or [SELECT] -- Open the input field ”Min. level” i
xxx [ENTER] -- Enter appropriate lower limit.
Enter upper limit
The maximum weight of the packages can be preset here
. The preset TOmaxi is
then no longer possible.
or [ ] -- Select the input field ”Max. level”.
or [SELECT] -- Open the input field ”Max. level” i
xxx [ENTER] -- Enter appropriate upper limit.
Presetting number of packages for mean value calculation
If the statistics type “self --adapting mean value” is preset, the number of accepted
packages may be entered here. The calculation of the mean value is made upon
this number. Please note:
Small number: Fast reaction to deviations in weight, but easily suscepticle to
interferences
Big number: Slower reaction to to deviations, but less susceptible to intefe-
rences.
or [ ] --
Select the entry field ”No of packages for st. mean value”
or [SELECT]
-- Open the entry field ””No of packages for st. mean value””
xxx [ENTER] -- Enter number of packages for mean value calculation.
Activate statistics display
The result of the statistical evaluation can be shown continuously in numeric and
graphic representation in the display (see page 3 -- 82 on). The weight class co-
lumn from which the statistical evaluation is to be displayed can be preset here.
Normally the evaluation of the middle weight class column with the preset nominal
weight Qn is shown.
or [ ] -- Select the entry field ”Statistics display”
[TOGGLE] -- Activate ( x ) or deactivate ( -- ) statistics display.
3