Presettings
Operating instructions GLP
3 -- 151
6.562.98.5.01.18
Scanning rules must only be changed when the user is well fami-
liar with the rules and the scancode applied to the packages. In-
correct changes prevent the scancode from being correctly read
and evaluated.
Scanning rules may be changed in respect of their code content. The content can
be replaced. There is also the possibility of changing the number of digits and the
decimal place formats.
Selecting the code digit place which is to be changed:
Move the cursor to the beginning of the code contents to be changed using the
cursor key [ ] or [ ]. The complete code contents may then be deleted and
replaced as required, or additional code contents may be inserted, or only the num-
ber of digits, or the decimal place format of the code contents changed.
Deleting code contents:
[ ] [ ] -- Move the cursor to the beginning of the block to be deleted, e.
g., to the lot number using the cursor keys.
Display: Ignore {1} PLU No. {4digits}
L
ot No. {2 digits} ......
[CLEAR] -- Delete the selected code contents.
Display: Ignore {1} PLU No. {4 digits}
}
Inserting a different code content:
[SELECT] -- Activate the code content selection.
-- Select, for example, the new code content, such as “Code
substring1” and code substring format “6--digit” as descri-
bed on page 3 -- 152.
Display: Ignore {1} PLU No. {4 digits} code substring1 {5--digit}
}
Changing the number of digits or decimal digit places:
[ ] [ ] --
Move the cursor to the relevant number of digits or the decimal
place format using the cursor keys, e. g. the number of digits of
code substring 1.
Display: Ignore {1} PLU No. {4 digits} code substring1
{
5--digit} }
[CLEAR] -- Delete the current number of digits or the decimal place for-
mat. The relevant selection menu is called up automatically.
Display: Ignore {1} PLU No. {4 digits} code substring1 {} ...
-- Select a new number of digits, e. g. 8, and acknowledge as
described on page 3 -- 152.
Display: Ignore {1} PLU No. {4 digits} code substring1 {8--digit}
}
Storing the changed scanning rules:
[ENTER] -- The changed scanning rules may be stored under the pre-
vious or a new number as described on page 3 -- 155.
3