Presettings
Operating instructions GLP
3 -- 156
6.562.98.5.01.18
3.8.4.4
Troubleshooting when the optional scanning element is absent
How to react to an absent scanning element marked as ’optional’ in the scanner
result may be preset here. This presetting does not affect scanning rules which
have no optional scanning elements.
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] 2 [ETC]
Printer&
interface
Scanner
-- Call up the selection menu.
If scan.
Dial.
elem. abs.
Del.
Setting troubleshooting
Dialog: if an optional content is not contained in the scancode, a
dialog will be indicated for the input of the necessary data enabling
the user to select a manual input of data or delete the content.
In the event that a complete optional AI is absent in EAN128, the
complete data of the AI is to be entered in a dialog.
Delete: if an optional content is not contained in the scancode, the
data field will be deleted (numeric data fields = 0).
The absense of a data content in an optional AI causes the relevant
field to be deleted.
In the event that a complete optional AI is missing, all data contents
of the AI will be deleted.
Standard setting: Delete
3.8.4.5 Reaction during scanning error
How to react when the scanned code is not conform with the presettings of the
scanning rules may be preset here.
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] 2
Printer&
interface
Scanner
-- Call up the selection menu.
Scan. err
Yes
Pckg rej.
Set error recovery
Yes: After a scanning error a dialog appears and prompts the ope-
rator to enter the faulty code manually.
No: No dialog appears after the scanning error. In automatic mode
the package is marked as a faulty package. A release command
possibly in the scanning instructions is sent (”Release package
WB” or ”Package Coming”). The scan string is not sent!
Standard setting: dialog
3.8.5 Assigning code field for Smart Label
If Smart Label or RFID labels are printed with the labeler, you may assign the re-
spective code field as described on page 3 -- 32 .
3