Status messages
Operating instructions GLP
4 -- 1
6.562.98.5.01.18
4 NOTES
4.1 STATUS MESSAGES
After activation of unit, during labeling and function calls or after selection of
presettings, diverse status messages may be displayed. They appear in a display
frame or in lieu of the weight display. All status messages the cause of which may
be eliminated by the operator himself, are combined in groups and described in
the following with their cause and remedial action. For other status messages not
listed here, please contact your local Bizerba representative.
Important status messages are stored in a memory and can be displayed for
analysing errors. This is described on page 3 -- 168.
Function softkeys are displayed in the lower softkey bar, depending on the status
or error message. Using these softkeys it is possible to acknowledge the
respective messages, to react to them or to display further messages etc.
If a lock is set when calling up invalid functions or bad data (e.g. missing PLU
number or PLU data) which means further labeling is locked. In addition, an error
message is displayed (see example).
P L U: PLU not available
Close
P
r
o
c
e
s
s
b
l
o
c
k
e
d
:
window
Description of the softkeysfor processing error messages:
Use Close window” to close the window, but a possible Lock is
not canceled.
Use Accept to cancel the locked processing and the Lock.
However, the indicated error must be eliminated!
Use Cancel to clear the display. Processing remains locked
(Lock)!
Use Acknowledge to confirm each error message individually.
Use Acknowledge all to confirm all error messages at one go.
Use Next message” if several messages are displayed, so the
next message to be displayed can be called up.
Use Details to display further information on remedy in case of
error messages
Use Solve problem to directly access a selction menu, where the
possibilities for error elimination can be selected.
Use Error list” to display the error list (see example on page
4 -- 2).
Back [ESC>
Press [ESC] to exit the error list.
Press [ENTER] to acknowledge input, selection or error message.
[CLEAR] Use the CLEAR--key to display the cause for a lock.
4.1
Close
window
Accept
Cancel
Acknowledge
Acknowledge
all
Next
Message
Details
Solve
problem
Error list
OK [ENTER]