15
0 3 I N S TALLING YOUR METER SENSOR
TYPE 3—ELECTRONIC WITH OPTICAL PORT ON TO P
14
Status
Indicator
C . Install Your Meter Sensor
The objective of this step is to align the Sensor
LEDs dire c t l y over the optical port on the mete r.
1. S t and dire c t l y in front of your electric mete r, at
a height where you can see the optical port .
The optical port itself looks like a small
p r o t ruding pipe in the center of the top port i o n
of the electric mete r. Ca re f u l l y wipe the mete r
dome clean with the damp cloth.
2 . Peel the adhesive backing off of the te m p l a t e.
Hold the te m p l a te with the pro t r uding tab fa c i n g
you and the arrow pointing away from yo u .
3 . S t i c k the te m p l a t e onto the meter with the
a r r ow pointing at, but not cove ring the optical
p o r t . You can peel the te m p l a t e off the glass
and realign it if necessary.
4 . Align the edges of the sensor with the white
side lines on the te m p l a t e. Slide the Mete r
Sensor over the glass dome as far as it will go.
5 . Ti g h t en the clamp until the Meter Sensor
is snu g , but can move just enough to allow
for adjustments.
6 . Open the Sensor A rm Latch Cover and
look down the opening.Yo u ’ll see a ve rt i c a l
plastic tab painted white on the inside of the
Sensor body.
7. Look through the opening and confi rm that the
tip of the white plastic tab on the Sensor is
lined up with the arrow line on the te m p l a t e.
Adjust the position of the sensor if necessary.
8 . Press the RESET bu tto n . Within 10 seconds,
the STATUS indicator will light solid red while
the Meter Sensor looks for a signal from the
m e t e r. When the Sensor is corre c t l y aligned,
the Status indicator will bl i n k .
Reset
Button
4 . Tu rn the Sensor A rm so that the two Sensor
LEDs are visible (4). T h e y need to be able to see the
Optical Po rt on the mete r .
5 . Push the smaller end of the Sensor A r m upwa r ds
t h r ough the latch opening and press the Sensor A rm
fi r m ly into the cavity (5).
6 . Slide the Sensor A rm as far down as it will go into the
b o ttom cavity of the body. If necessary, use a dull
p o i n t ed object, such as a ballpoint pen, to push it all the
way down (6). The two Sensor LEDs must be visibl e .
7. Tu c k the wire into the side cavity (7).
8 . Close the latch (8).
9 . Re t h read the clamping strap into the sensor
housing and re a ttach the ends. Tu r n the screw
as you feed in the end to re a t tach it.
Sensor LED’s