BLACKMER LIQUEFIED GAS PUMPS
960425
INSTRUCTIONS NO. 501-D00
FOR LP-GAS AND NH
3
SERVICE
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS
MODEL: TLGLF3C
Section
Effective
Replaces
501
Jan 2014
Aug 2010
Patent Protected by U.S. Patent 6030191 and Related Foreign Patents.
TABLE OF CONTENTS Page
SAFETY DATA .................................................................. 1
PUMP DATA ...................................................................... 2
Pump Identification ..................................................... 2
Technical Data ........................................................... 2
Initial Pump Start Up Information ............................... 2
INSTALLATION
Welded Connections .................................................. 3
Pump Mounting .......................................................... 3
Pre-Installation Cleaning ............................................ 3
Location and Piping .................................................... 3
Auxiliary Inlet .............................................................. 3
Pump Drive ................................................................ 4
Hydraulic Drive ........................................................... 4
Pump Relief Valve and Bypass Valve ........................ 4
Pump Rotation ........................................................... 4
OPERATION
Pre-Start Up Check List ............................................. 5
Start Up Procedures ................................................... 5
Pump Speed .............................................................. 5
MAINTENANCE ..................................................................
Lubrication .................................................................. 6
Vane Replacement ..................................................... 7
Pump Disassembly .................................................... 7
Pump Assembly ......................................................... 8
TROUBLE SHOOTING .................................................. 10
NOTE: Numbers in parentheses following individual parts
indicate reference numbers on Blackmer Parts List 501-D01
Blackmer pump manuals and parts lists may be obtained from
Blackmer's website (www.blackmer.com) or by contacting
Blackmer Customer Service.
SAFETY DATA
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the manual,
look for one of the following signal words and be alert to the
potential for personal injury, death or major property damage
Warns of hazards that WILL cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury
or property damage.
NOTICE:
Indicates special instructions which are very
important and must be followed.
NOTICE:
Blackmer liquefied gas pumps MUST only be installed
in systems which have been designed by qualified
engineering personnel. The system MUST conform to
all applicable local and national regulations and safety
standards.
This manual is intended to assist in the installation
and operation of the Blackmer liquefied gas pumps,
and MUST be kept with the pump.
Blackmer liquefied gas pump service shall be
performed by qualified technicians ONLY. Service
shall conform to all applicable local and national
regulations and safety standards.
Thoroughly review this manual, all Instructions and
hazard warnings, BEFORE performing any work on
the Blackmer liquefied gas pumps.
Maintain ALL system and Blackmer liquefied gas
pump operation and hazard warning decals.

Questions and Answers

  • J
    Joshua JonesAug 5, 2025
    Why is my BLACKMER TLGLF3C Water Pump capacity reduced?
    • C
      cboydAug 5, 2025
      There are several potential reasons for reduced capacity in your BLACKMER Water Pump. The pump speed might be too low, or the internal control valve may not be fully open. There could be excessive restriction in the inlet line due to undersized piping, too many elbows and fittings, or a clogged strainer. Damaged or worn parts like vanes, cylinder, or rotor can also cause this issue. Other possible causes include excessive restriction in the discharge line, a worn or improperly set relief valve, an external bypass valve set too low, operating without a vapor return line, incorrectly installed vanes, or a liner installed backwards.
  • C
    Chad Carson MDAug 12, 2025
    Why is my BLACKMER Water Pump making noise?
    • L
      lchambersAug 12, 2025
      Several issues can cause noise in your BLACKMER Water Pump. These include excessive pressure drop due to undersized or restricted fittings in the inlet line, pump speed being too fast, or the pump being too far from the fluid source. Running the pump for extended periods with a closed discharge line can also cause noise. Other potential causes are: 1. The pump not being securely mounted. 2. An improper drive line in truck-mounted pumps. 3. Misalignment of pump, reducer, or motor in base-mounted pumps. 4. Worn or damaged bearings. 5. Vibration from improperly anchored piping. 6. A bent shaft or misaligned drive coupling. 7. An excessively worn rotor. 8. A malfunctioning valve in the system. 9. A relief valve setting that is too low. 10. A liner installed backwards. 11. Damaged vanes.
  • P
    Perry ReeseAug 20, 2025
    What causes damaged vanes in BLACKMER TLGLF3C Water Pump?
    • E
      Elizabeth RoachAug 20, 2025
      Damaged vanes in your BLACKMER Water Pump can result from several causes, including foreign objects entering the pump, running the pump dry for extended periods, cavitation, or excessive heat. Other potential causes include worn or bent push rods, worn push rod holes, hydraulic hammer (pressure spikes), incorrectly installed vanes, or incompatibility with the liquids pumped.
  • E
    Emily MaciasAug 27, 2025
    What causes a broken shaft in BLACKMER Water Pump?
    • T
      Todd HamiltonAug 27, 2025
      A broken shaft in your BLACKMER Water Pump can occur due to foreign objects entering the pump, the relief valve not opening, or hydraulic hammer (pressure spikes). Misalignment of the pump/driver or driveline/drive shaft can also cause this issue, as can excessively worn vanes or vane slots.

Summary

SAFETY DATA

Safety Warnings and Precautions

Covers DANGER, WARNING, CAUTION, and NOTICE statements regarding hazards and important instructions.

INSTALLATION

Pump Relief Valve and Bypass Valve

Notes on internal relief valve settings and external bypass valve requirements.

OPERATION

Start Up Procedures

Detailed step-by-step instructions for safely starting the pump.

MAINTENANCE

Pump Disassembly

Step-by-step instructions for disassembling the pump for maintenance.

Pump Assembly

Step-by-step instructions for reassembling the pump after maintenance.

Mechanical Seal Installation

Instructions for installing the mechanical seal rotating assembly and stationary seat.

Locknut Adjustment

Procedure for adjusting bearing locknuts to ensure proper rotor alignment and bearing preload.

TROUBLESHOOTING

Pump Not Priming

Lists probable causes and solutions for pump priming failures.