Pump performance / flow chart
GETTING TO KNOW YOUR INPOND
5
C
C
_
Cable Fitted 13 metres
Voltage 12V
Watts 10
Safety Rating IP68
Maximum Depth 1.25 metres
Maximum Lift 1.25 metres / 4’1”
Lift Flow rates lph
2.0 metres -
1.5 metres -
1.0 metres 300 lph
0.5 metres 520 lph
0.0 metres 700 lph
Flow is given as optimum rate
Tech Specification:
Pump
700ltr (154 gal)
1.25m max head (4.1”)
12v Low voltage
IP56 Weatherproof transformer
10m of low voltage cable
10w IP68
LED
Photo sensor activated
0.76w
UVC
5w PL lamp
13m of cable
230v 50Hz
IP68
Specification chart
No. Part Description Spare Code
39. PL 5W UVC lamp 1041041
40. Quartz sleeve N/A
41. UVC O ring N/A
42. 13m cable N/A
43. IPX7 Starter UVC + 10m of cable N/A
INSTALLATION
For permanent installations to the mains supply, it is necessary to conform to
the regulations of the local electricity authority and this would include the use
of a metal or plastic conduit to protect the cable.
Attention has been drawn to the fact that special rules may exist concerning
the installation of your pond pump (i.e. local building regulations).
These pumps must not be used in swimming pools, or areas where people are
in contact with the water.
Always disconnect the mains electricity supply whilst the equipment is being
installed, repaired, maintained or handled. Consult a qualified electrician if in
any doubt about wiring this product to the main supply.
Warning - The Inpond pump is provided with a thermal
cut out that temporarily switches off the pump in case of
overheating and the pump may automatically restart.
4
Electrical installation
The power supply must meet the specifications on the product.
The pump is intended to be used with either a weather-proof
cable connector or permanently connected to the fixed wiring
in the main system other than by means of a plug and socket.
The cores in the supply cable are coloured in accordance with the following
code: Brown = Live, Blue = Neutral, Green/Yellow = Earth.
The electric cable is permanently connected and sealed in the motor body.
If the supply cable is damaged the pump must not be used.
Do not use the supply cable to lift the pump as this may cause damage.
WARNING - THIS PUMP MUST BE EARTHED
A Residual Current Device (RCD), also know as the Residual
Current Circuit Breaker (RCCB), with a tripping current not
exceeding 30mA must be installed in the supply circuit.
A means of disconnection from the supply having a contact separation
of at least 3mm in all poles must be incorporated in the fixed wiring.