BURNERS DISPOSITION AND TECHNICAL DATA TABLE
N. BURNER GAS
Operating
Pressure kPa
Diameter
Injectors 1/100
mm
Rating
MJ/h
2
Large
Left front
U-LPG
Natural
2.75
1.00
88
142
10.0
10.0
3
Medium
Right and left
rear
U-LPG
Natural
2.75
1.00
73
120
7.2
7.2
4
Small
Right front
U-LPG
Natural
2.75
1.00
54
90
3.8
4.0
6
Wok
central
U-LPG
Naturall
2.75
1.00
105
175
14.6
15.0
ELECTRICAL COMPONENTS DESCRIPTION NOMINAL DATA
Lower heating element of the oven
Top heating element of the oven-grill
Circular rear heating element of the oven
Oven lamp
Oven cooling fan
Fan of the rear heating element
Supply cable
Plug
1850 W
1400+2000 W
2 X 1600 W
15 W - E 14 - T 300
12 W
(4)x 20 W
H05 RR-F 3 x1.5 mm
2
2P + T - 15 A
ELECTRICAL TECHNICAL DATA
Voltage - Frequency 240 V~ 50 Hz
TECHNICAL FEATURES
GAS TECHNICAL DATA NATURAL GAS - U-LPG
BFD915WX
Operating pressure gas kPa 1.00 kPa - 2.75 kPa
Total input gas MJ 43.4 - 42.8