www.blastrac.com ‒ custserv@blastrac.com
4/17
GB
EC Declaration of conformity
Every vacuum cleaner comes with a EC Declaration of
conformity. See fac-simile in g. 17.
[ NOTE ]
The Declaration of conformity is an important
document and should be kept in a safe place to be
presented to the Authorities on request.
Classication in compliance with
standard EN 60335-2-69 – Annexe
AA
Vacuum cleaners for dust harmful to health are
classied according to dierent dust classication:
■ L (low risk) suitable for separating dust with an
exposure limit value of over 1 mg/m
3
, depending
on the volume occupied;
■ M (medium risk) suitable for separating dust with
an exposure limit value of no lower than 0.1 mg/
m
3
, depending on the volume occupied;
■ H (high risk) for separating all dust with an
exposure limit value lower than 0.1 mg/m
3
,
depending on the volume occupied, including
carcinogenic and pathogenic dusts, such as
asbestos.
Dust emissions in the environment
Indicative values of performance:
■ Version for dust harmful for the health:
L: retains at least 99% of vacuumed particles
(see EN 60335-2-69, Annexe AA);
M: retains at least 99.9% of vacuumed particles
(see EN 60335-2-69, Annexe AA);
H: retains at least 99.995% of vacuumed
particles (see EN 60335-2-69, Annexe AA).
General recommendations
WARNING!
If an emergency situation occurs:
■ lter breakage
■ re outbreak
■ short-circuit
■ motor block
■ electric shock
■ etc.
Turn the vacuum cleaner o,
unplug it and request assistance
from qualied personnel.
WARNING!
The vacuum cleaners must not
be used or stored outdoors, or in
damp places.
Only versions with the level sensor can be
used for liquids, if not, they can only be used
to vacuum dry materials.