1) Take out the outer connector assembly and the exhaust pipe assembly, and remove
the plastic bags;
2) Insert the heat pipe assembly (the end of the exhaust joint) into the back panel vent
slot (push to the left) and complete the assembly (as shown in gure 1).
1.2 Installation of window sealing plate components
1) Half open the window,and mount the window sealing plate assembly to the window
(as shown in Fig.2 and Fig.3).Components can be placed in horizontal and vertical direction.
2) Pull various components of the window sealing plate assembly open, adjust their
opening distance to bring both ends of the assembly into contact with the window
frame, and x various components of the assembly.1.2 Install the window sealing plate
assembly
Notes:
1) The at end of the exhaust pipe joints must be snapped into place.
2) The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep the
ventilation of the exhaust pipe not blocked.
1.3 Install the body
1) Move the machine with installed heat pipe and ttings before the window, and the
distance between the body and walls or other objects shall be least 50 cm (as shown in Fig.4).