8 102619 03/13
Operating Instruction
Inspectionandservicing
Oilandwaterseparator
Istteddownstreamofthecondensationwater
drain.Theseparatedwatercanberemoved
directlyintothesewersystem.
Rubber-metalconnection
Toreducevibrations.
Sound-absorbinghood
Toreducenoiseemissions.
Formoreinformationontheseand
otherpneumaticaccessories,pleasere-
fertoBLITZ.Ouraddressisonthelast
pageoftheseoperatinginstructions.
5 Inspection and servicing
5.1 Safetyinstructions
Theinspectionandservicingmaybecarried
outbyexpertsortrainedpersonsonly.
• Switchthecompressoroffforallservicing
work,andprotecttheunitagainstunintenti-
onaloperation.
• Priortoanyservicingworksetthepower
switchtoofforremovethemainsplug.
• UseoriginalBLITZpartsandapproved
operatingmaterialonly.
• Afterhavingcompletedtheservicingwork
tightenallscrewsagain.
• Depressurisethecompressorpriortoany
servicingwork.
• Touchthecompressorsystemattheon
andoffswitchonlyduringandshortlyafter
operation.Permitthecompressortocool
downpriortoanyservicingwork.Hotsur-
facescancausesevereinjuries.
5.2 Checkingandtoppinguptheoil
level
2
1
3
Fig.3:Compressoraggregate
1 Oilinspectionglass
2 Oildrainplug
3 Oilllerneck
Checkingtheoillevel
Usetheoilinspectionglass1tocheckthe
oillevel.
Theoillevelhastobewithintheredcircle
intheoilinspectionglass.
Checkwhethertheoilhasamilkydiscolo-
rationorcontainswaterdrops(formeasu-
res,pleaserefertochapter7titled“Trouble
shooting/Milkycolouroftheoil,water
dropsintheoil”).