Operating instructions
TWIN piston compressors
TWIN piston compressors, wheeled
Type
Serial number
Date
Rev. E 102620 05/2019

Questions and Answers

  • C
    Colleen MedinaAug 17, 2025
    What to do if my Blitz VARIS does not start up?
    • A
      Ashley ArnoldAug 17, 2025
      If your Blitz Air Compressor isn't starting, first ensure it's properly connected to the mains. Next, check the electric cable, switching units, and motor for blown fuses, replacing them with time-lag fuses if necessary. Also, verify that the network pressure isn't exceeding the cut-in pressure; reduce it if it is. If these steps don't resolve the issue, the pressure switch or the motor itself might be defective and require replacement. Finally, consult the table regarding the protective motor switch in case it has been triggered.
  • N
    Nancy CoxAug 20, 2025
    Why has the protective motor switch been triggered on my Blitz VARIS?
    • J
      James BanksAug 20, 2025
      If the protective motor switch on your Blitz Air Compressor has been triggered, start by checking its setting. Then, inspect the electrical connection for undervoltage, phase failure, and the conductor cross-section. High ambient temperature can also cause this, so improve room ventilation or relocate to a cooler spot. Check for damage to valves, the crank mechanism, and the fan. Ensure the compressor is relieved by checking the relief mechanism and replacing the check valve if needed. Also, examine the pressure switching points and retighten any loose clamping connections.
  • C
    Courtney SchaeferAug 23, 2025
    Why is my Blitz VARIS Air Compressor turning too hot?
    • K
      Kristen TurnerAug 23, 2025
      If your Blitz Air Compressor is turning too hot, try improving room ventilation or moving it to a cooler location to lower the ambient temperature. Check that the cooling air volume is sufficient and that the space between the fan and wall isn't too small; also, clean the fan cowl opening if it's soiled. Ensure the fan is rotating in the correct direction. Inspect the compressor valves, replacing them if they're defective. Finally, verify that the ultimate pressure isn't too high by checking the pressure switching points.
  • A
    alison54Aug 26, 2025
    What causes low delivery in my Blitz VARIS?
    • M
      Megan BrandtAug 26, 2025
      If your Blitz Air Compressor has low delivery and isn't reaching the setpoint pressure, start by checking the valves and replacing them if necessary. Then, inspect the suction filter for soiling, cleaning or replacing the filter cartridge as needed. Tighten any leaking screws and fittings, replacing the seals. If the cylinder head seal is leaking, tighten the cylinder head screws or replace the seal. Check the piston, piston rings, and cylinder for wear, replacing worn parts. Also, check the pressure switching points. Finally, compare the air demand to the compressor's delivery volume and expand the compressed air supply if needed.
  • R
    Rachel PayneAug 28, 2025
    How to reduce the switching frequency of my Blitz Air Compressor motor?
    • M
      Matthew SmithAug 28, 2025
      If the switching frequency of your Blitz Air Compressor's motor is too high, consider using a larger compressed-air reservoir. Also, check the pressure switching points. Ensure you drain condensation water regularly, and consider fitting an automatic condensation water drain system as a preventive measure.
  • J
    James SantosAug 31, 2025
    Why is the oil in my Blitz Air Compressor milky?
    • V
      veronica19Aug 31, 2025
      If the oil in your Blitz Air Compressor appears milky or contains water drops, change the oil immediately. This can be due to water in the crankcase because the operating temperature isn't being reached due to short cut-in times, so consider retrofitting a crankcase heater if possible, selecting a warmer location, and checking the compressor setting. It can also be caused by humid conditions, so select a dry location.
  • E
    ebrockSep 3, 2025
    What causes high oil consumption in my Blitz VARIS?
    • B
      brianponceSep 3, 2025
      If your Blitz Air Compressor is consuming too much oil, first check the type of oil being used and replace it if it's incorrect. Inspect the piston rings and cylinder face for wear, replacing them if necessary. Also, check the suction filter cartridge and replace it if needed. Refer to the 'Compressor turns too hot' section for guidance if the compressor is overheating. Finally, check or replace the crankcase breather if oil is escaping through it.
  • T
    Terry BrownSep 8, 2025
    Why is air escaping from the relief pipe of my Blitz VARIS when it is off?
    • C
      christopher55Sep 8, 2025
      If air escapes through the relief pipe of your Blitz Air Compressor when it's at a standstill, check the check valve and replace it if necessary.
  • N
    Nicole CastroSep 12, 2025
    Why is air escaping through the relief valve during operation of my Blitz VARIS Air Compressor?
    • J
      Jennifer AguilarSep 12, 2025
      If air escapes through the relief valve of your Blitz Air Compressor during operation, the relief valve is likely defective and needs to be replaced.
  • P
    Paula ReynoldsSep 13, 2025
    What to do if my Blitz VARIS is not relieved when switched off?
    • A
      Amanda Davis DDSSep 14, 2025
      If your Blitz Air Compressor is not relieved when switched off, check the pressure switch and the relief valve, and replace them if necessary.

Summary

Transport and Storage

Transport Procedures

Safe procedures for transporting the compressor, including lifting and securing.

Mounting and Installation

Electrical Connection and Conditions

Procedures, safety, and network requirements for connecting to power.

Operation

Operational Safety Instructions

Essential safety measures to observe during compressor operation.

Inspection and Servicing

Servicing Safety Precautions

Safety precautions to be taken before and during inspection/servicing.

Maintenance Schedule

Trouble Shooting

Compressor Fails to Start

Potential reasons and solutions for the compressor failing to start.

Protective Motor Switch Issues

Diagnosing and resolving issues related to the protective motor switch.