- 35 -
Test Functions, Steam Generator
How to set the water level:
1. Empty steam generator and read sensor input.
2. Fill steam generator until water level is high, and read sensor input.
3. Set level to a value between high and low sensor input.
4. Conclude by pressing OK.
Cannot be activated until
water level in steam
generator is high and main
contactor is active.
Not active
INFO: Current temperature
in steam generator
INFO: Water level in steam
generator (high or low)