- 52 -
Error Codes
Generator too hot (Generator thermo-switch has tripped. Reconnect by pressing button
under operation panel)
Oven too hot (oven thermo-switch has tripped. Reconnect by pressing button under
operation panel)
Fan too hot (Thermo-switch in motor has tripped. Wait for 10 min. and try again.)
Drain too hot (Drain temperature has been too hot (above 165F (75C) for more than 5
min. Check that jet in drain is working. Check for dirt in solenoid valve, jet or dirt filter.
Check if by mistake hot water has been connected. Check if sensor is defective or jet is
sprinkling in the wrong direction.)
Oven sensor defective (Temperature sensor in oven not working properly. Check wire
connections or replace sensor)
Core temp. probe not connected (A program using core temp. probe has been selected
but probe has not been connected)
Generator sensor defective (Temperature sensor in generator not working. Recipes
prescribing use of steam generator cannot be used. Check wire or replace sensor.)
Drain sensor defective (Sensor in drain not working. Oven can still be used. Check wire
connections or replace sensor.)
Water shortage (Steam generator was not filled within two minutes. Check that the water
has been turned on. Check if solenoid valve or dirt filter is blocked. Check water pressure
(should be at least 2 bar))
SSR too hot. Thermo-switch for solid-state relay has tripped. Wait for 10 – 20 minutes and
try again. Check that the cooler opening is not blocked.)
Generator too hot (Temperature in steam generator higher than 266F (130°C). If error
recurs, descale generator)
Internal defect (Oven server process does not respond. Oven server process fails. Restart
oven)
Internal defect (Failure in communication between computer and IO board)
Invalid program (Program uses a function which the oven does not support)
Program interrupted (Power cut-out during program performance. Cut-out has lasted so
long that program cannot be restarted)
CombiWash (Oven is so hot that CombiWash cannot start. Cool oven and start again.
Draining defect (Steam generator could not be emptied during flushing. Level sensor
reports high water level when generator is emptied)
ClimaOptima (ClimaOptima not calibrated. Enter service menu and calibrate)
ClimaOptima (ClimaOptima sensor defective. Pressure sensor does not give out correct
signal.)
ClimaOptima (Calibration could not be performed. Start cal when oven is cold and dry)
Alarm defective (An invalid combination of the main alarms has been detected. The main
alarms are not shown correctly.)
Door sensor defective (Door sensor does not work. Note: Oven does not stop when door
is opened. Oven can still be used.)
Water pressure too low (Check that water is turned on)
Detergent insufficient (Detergent or rinse aid has run out)
Detergent in oven (CombiClean interrupted while detergent in oven chamber. Run
CombiWash step 0 before using oven. Food products and oven may be damaged if oven is
used before soap is removed.
Memory insufficient (Memory insufficient for this operation)
IO board hot (Internal temperature of IO board has been too high. Clean filter at the
bottom of the panel. This is a warning: If temperature rises further, oven stops showing
error code 16.
Main alarm (Steam generator thermo-switch has tripped during out-of-service time. Main
contactor disconnected.)
SW defect (An SW defect has been detected during operation. Steam generator activated
by mistake.)