- 28 -
Step Time Temp. Oven Exhaust
1 Cal. Abt 15 min, 70 Dry Open
2 Cal. Abt. 2 min. 70 Dry Open
3 Cal. Abt. 2 min. 70 Dry Closed
4 Cal. Abt. 8 min 250 Dry Open
5 Cal. Abt. 3 min. 250 Dry Closed
6 Cal. Abt. 5 min. 190 Wet Closed
7 Cooling Abt. 30 sec 105 Open
8 Cal. Abt. 5 min. 130 Wet Closed
9 Cooling Abt. 8 min. 45 Open
10 Cal Abt. 4 min. 70 Wet Closed
ClimaOptima Calibration
Calibration should be carried out when
CPU board is replaced
Differential pressure sensor is replaced
Fan wheel is removed and mounted again
or replaced.
Filter housing is replaced
The oven should be as dry as possible before calibration is carried out.
The oven temperature must not be higher than 100°F (40°C) when calibration is started.
NOTE: If calibration is started by mistake, turn off the oven (no other keys are active).
NOTE: Do not interrupt the calibration process.