8
kg
Tumble Dryer Service Handbook
31
5. Faults Algorithms :
No Power Supply
Check the
electrical
connections
Connect the power supply
NO
Check the
electricity on the
main control card
YES
Change the main card
NO
Check the on/off
switch
connections
Check the connections
NO
Check the
interfere filter
NO
Check the connections
Check the main control card and
change it if necessary