7
NOTE:
Only non-combustible materials can be used in close proximity to this appliance.
To facilitate easy operation, drainage and servicing of appliance, a minimum of
600mm clearance should be maintained at front of appliance.
Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. The following minimum installation clearances are to be adhered to:
This model is delivered completely assembled. Ensure that the legs are securely attached.
NOTE:
This appliance is fitted with adjustable feet to enable the appliance to be positioned
securely and level. This should be carried out on completion of gas connection. Refer
to 'Gas Connection' section below.
Optional Accessories (Refer to Replacement Parts List)
Plinth Kit. For installation details, refer to instructions supplied with each kit.
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON.
Flexible Hose Connection
If a Gas Hose assembly is used to connect this appliance, hose and all fittings must have a minimum
¾(Natural Gas) or ½(LPG) inside bore diameter to ensure gas flow rate capacity required by this
appliance is achieved.
This must be verified by operating pressure testing at maximum gas supply demand condition.
The Gas Hose assembly should also be classified for use in commercial kitchen conditions, appliance
will be used in.
Recommended Gas Hose Assembly Specification:
- AS/NZS 1869 Class B or D compliant or equivalent, that meets the following requirements:-
1. Blue Seal GT45 / GT46 / GT60 Fryers do not require an electrical connection, they function totally on
gas supply only.
Left / Right Hand Side 50mm 0mm
Rear 50mm 0mm
Class
Max Working Pressure
at 23 ± 2ºC
Working Temperature
Range
Resistance to Oil
B
7.0 kPa
- 20ºC to + 125ºC
Oil resistant lining
and cover.
D
2.6 MPa