How to resolve motor over current in Blue-White FLEXFLO A1 Measuring Instruments?
- KKevin ThompsonAug 5, 2025
If you're experiencing a motor over current issue with your Blue-White Measuring Instruments, make sure the tube is correctly installed.
How to resolve motor over current in Blue-White FLEXFLO A1 Measuring Instruments?
If you're experiencing a motor over current issue with your Blue-White Measuring Instruments, make sure the tube is correctly installed.
What to do if the motor stalls in Blue-White FLEXFLO A1 Measuring Instruments?
If the motor stalls in your Blue-White Measuring Instruments, verify that the tube is properly installed.
What to do if temperature exceeds 75°C at control in Blue-White Measuring Instruments?
If the temperature exceeds 75°C at the control for your Blue-White Measuring Instruments, check the ambient conditions and restart the pump once it has cooled to ambient temperature.
Details the different models of the FLEXFLO Series A1 peristaltic metering pump, including tube size and material.
Lists materials for pump tube assembly, adapter fittings, and injection/back-flow check valve components.
Details materials for enclosure, pump head, roller assembly, sensors, and other external parts.
Information on ETL, Intertek, CE certifications and compliance with relevant directives and standards.
Guidance on selecting an appropriate location for the pump, considering supply, injection, and service access.
Step-by-step instructions and diagrams for securely mounting the pump to a wall.
Instructions for assembling and installing the discharge injection fitting and suction strainer.
Steps to program the Flow Verification Sensor (FVS) settings on the pump's touchpad.
Details the USB-C and M12 connectors on the pump's right side panel and their functions.
Explains the pin assignments and functions for M12 input and output connectors.
Steps to select the 4-20mA input mode using the pump's touchpad interface.
Guide to setting minimum and maximum mA values and speed percentages for 4-20mA input.
Procedure to test the TFD+ system's ability to detect specific chemicals in the pump head.
Guidelines for weekly checks, identifying chemical attack, and replacing worn components.
Instructions for cleaning pump parts, motor shaft, and applying lubrication.
Identification of the specialized tool provided for tube installation and removal.
Step-by-step guide on how to safely remove the pump tube assembly from the pump head.
Detailed instructions for installing the new pump tube assembly into the pump head.
Visual representation of pump components with corresponding part numbers for identification.
Details the duration, coverage, and conditions of the pump's limited warranty.
Lists items and conditions that are not covered under the FLEXFLO Series A1 warranty.
Steps to follow for obtaining warranty service, including RMA and shipping instructions.
Important safety information and disclaimers regarding product use and suitability for applications.
Precautions and warnings related to chemical compatibility and potential damage to the pump.
| Model | FLEXFLO A1 Series |
|---|---|
| Category | Measuring Instruments |
| Motor | DC Motor |
| Control | Manual |
| Power Supply | 12V DC or 24V DC |
| Weight | 3 lbs |
| Output | 4-20mA |
| Temperature Range | 32°F to 130°F |