MAINTENANCE
Air shutter adjustments are pre-set at the factory. However depending on a variety of factors including the type of gas
supply, these adjustments may need to be fine-tuned after installation. A qualified installer should make these
adjustments at the time of installation.
Any air shutter adjustments that are needed after installation are not covered by your warranty.
Air Shutter Checklist
Before making any adjustments to the air shutters, verify the following:
1. Range is completely cool.
2. Gas source type (natural gas or liquid propane) matches the serial plate and is set properly. This setting is typically
checked and adjusted by a service technician using a manometer.
3. Gas pressure regulator is set properly to natural gas or liquid propane.
4. Orifice is aligned and parallel with the venturi tube to the burner, the venturi is properly positioned over the orifice, and
that the burner is properly seated.