12.2 Enable the UPS
12.2.1 Standard UPS Mode
AC300+B300 plays as a backup power source when the grid presents, immediately
charging your loads when the grid fails.
12.2.2 Time Control UPS Mode
AC300+B300 charges and discharges at specific time periods, greatly cutting your
electricity bills.
Charge Time: The period when AC300+B300 charges via the grid. Choose to
charge the system during off-peak hours when electricity prices are low.
Discharge Time: The period when AC300+B300 supplies power to your loads.
Parameter Setting:
Battery SOC Low: When the remaining battery capacity is lower than preset
charge value, the load will be powered by the grid in bypass mode. Setting it at 0
may cause the failure of bypass function.
Battery SOC High: When reaching the preset charge value,
AC300 will be recharged via PV instead of the grid.