LCD Screen- Fault Notification
Error Code Fault information Description Troubleshooting
Battery Low Voltage SOC≤4% Recharge
TEMP Abnormal temperature
1. When the AC part is higher than 80°C
2. When the DC part PD/DC12V is higher than 100°C
3. When the Charging part greater than 48°C or lower than 0°C
4. When the battery discharge temperature is greater than 65°C
lower than -20°C
1. Recover <75°C
2. Recover <95°C
3. Recover <95°C
4. Recover <50°C
OVERLOAD Output overload
AC overload: When the AC output power exceed 660W
Reduce load, press AC button to resume
SHORT Output short circuit
1. AC output short circuit, Turn OFF AC;
2. USB output short-circuit, Turn OFF DC;
3. DC12V output short circuit, Turn OFF DC;
Please disconnect the load to make sure
the output power of loads meet the limit
of the EB3A.