2 | P a g e
BLUEWORKS BLH Series
ELECTRONIC CHLORINE GENERATOR
Installation and Operation Manual
IMPORTANT SAFETY INSTRUCTIONS
When using electrical equipment, basic safety precautions should
always be exercised, including the following:
Cautions:
Please note, the total working hours for the T-Cell should be less than
8 hours total per day. If you are using a variable speed pump for 24
hours a day be sure to adjust the chlorine output to 25-30%. If the
pump is only running 10 hours per day adjust the chlorine output
between 60-80%.
You can use this calculation to calculate the appropriate chlorine
output for your pool, suggest at 6 hours per day.
Pump running 24(Hours a day) *25% (Chlorine Output) =6hr (cell run time per day at 25%).
Pump running 20(Hours a day) *30% (Chlorine Output) =6hr (cell run time per day at 30%).
Pump running 15(Hours a day) *40% (Chlorine Output) =6hr (cell run time per day at 40%).
Pump running 12(Hours a day) *50% (Chlorine Output) =6hr (cell run time per day at 50%).
Pump running 8(Hours a day) *75% (Chlorine Output) =6hr (cell run time per day at 75%).
Start the VS pump on a low speed and kick the speed up until the salt
system works.