21 | P a g e
turned on.
• For Canadian models, the BLH shall be connected to a circuit protected by a class
A ground fault interrupter. Be sure to connect the GROUND wire to the green
ground screw terminal located on the INSIDE WALL of the enclosure.
Note: Wire the pump directly to the time clock—do not use the BLH as a junction box.
Bonding:
A lug used for bonding is attached to the bottom of the BLH enclosure (see diagram below).
The BLH must be bonded with an 8 AWG copper wire (6 AWG Canada) to the pool bonding