Instruction leaet
SERVO-DRIVE plug-in transformer Z10NA300
Technical data
The appliances must only be used in dry, closed rooms. All SERVO-DRIVE appliances are of protec-
tion class III and must only be supplied with safety extra-low voltage (SELV). They are only to be used
with the transformers provided by Blum.
Input voltage: ............................................................................................... 100–240 V AC / 50–60 Hz
Input current: ................................................................................................................................. 0.3 A
Output voltage: ..................................................................................................................... 24.0 V DC
Output current: ............................................................................................................................... 0.5 A
Output power: ............................................................................................................................. 12.0 W
Average active efficiency: ........................................................................................................... 83.3 %
Efficiency at low load (10%): ...................................................................................................... 78.0 %
No-load power consumption: ................................................................................................... ≤ 0.08 W
Ambient conditions:
Transport / Storage: ......................................................................... -30 to +70 °C / 0 to 90 % r.H.
Operation: ................................................................. 0 to +40 °C / 5 to 80 % r.H. non condensing
Maximum altitude: ................................................... 2000 m (at an ambient temperature of 25 °C)
Protection category: ................................................................. IP40 (if cable end protector is inserted)