Do you have a question about the BLUM SERVO-DRIVE uno and is the answer not in the manual?
Power supply | 24 V DC |
---|---|
Protection class | IP20 |
Type | SERVO-DRIVE uno |
Motor type | DC Motor |
Storage temperature | -20°C to +60°C |
Defines the meaning of the WARNING symbol indicating potential death or serious injury.
Identifies the symbol for appliances intended only for indoor use.
Identifies terminals that must not be connected to mains voltage.
Mains plug and SERVO-DRIVE transformer must be easily accessible.
Transformer and cabling must not contact moving parts.
Guidelines for safe use by children aged 8+ and those with reduced capabilities.
Specifies maximum cable length for specific SERVO-DRIVE plug-in transformers.
Requirement for earth connection for SERVO-DRIVE transformer Z10NE030.
Only original spare parts from Julius Blum GmbH are permitted.
Only SERVO-DRIVE components should connect to the transformer.
Only qualified specialists may install or modify components and cabling.
Ensure the Blum distance bumper is attached to the front.
Recommends connecting the transformer to a switched outlet to prevent unintentional activation.
A 30 mm safety distance is required for air circulation to prevent overheating.
Children should be supervised to prevent them from playing with the lift system.
Turn off the switched outlet to prevent unintentional triggering of SERVO-DRIVE.
Warning about electric shock if fluids penetrate the SERVO-DRIVE transformer.
Turn off the switched outlet and unplug the transformer before cleaning.
Use a moist cloth; avoid water or aggressive cleaning materials on drive unit or transformer.
Never open the SERVO-DRIVE transformer, drive unit, or switch.
Any cabling damage must be corrected by a qualified specialist.
Do not cover the transformer to avoid overheating.
Frequently examine the appliance for signs of wear or damage.
SERVO-DRIVE transformers provide power to the drive unit and can be checked via the LED.
Improper use can cause premature wear on pull-out systems.
Do not press or pull against the movement direction when opening/closing drawers.
Explains how the drive unit lever opens the drawer a short distance upon touch or pull.
The opening function is triggered by brief touch/pull, not leaning.
Blum distance bumpers ensure a 2mm gap for correct triggering.
No items should be clamped between the pull-out unit and the cabinet back.
Blum appliances meet WEEE Directive requirements for recycling and environmental protection.
Information on returning electrical and electronic appliances for reuse or recycling.
Batteries meet Battery Directive requirements for recycling and environmental protection.
Information on returning batteries and avoiding shorting contact surfaces.
Details input voltage (100-240 V AC) and current (0.3 A) for the transformer.
Details output voltage (24.0 V DC) and current (0.5 A) from the transformer.
Specifies output power (12.0 W) and efficiency ratings.
Details no-load power consumption and ambient conditions for transport, storage, and operation.
Specifies maximum operating altitude and protection category (IP40).
Details input voltage, current, output voltage, current, and power for the Z10NA40x* transformer.
Specifies efficiency, low load efficiency, and no-load power consumption for the transformer.
Details ambient conditions, maximum altitude, and protection category for the transformer.
Specifies supply voltage (24.0 V DC) and rated current (2.0 A) for the drive unit.
Details standby power consumption and operating mode (S3 5%).
Provides emission sound pressure level and ambient conditions for the drive unit.
Specifies maximum operating altitude and protection category (IP20) for the drive unit.