14
Symbol Value Unit
Rated capacity for cooling P
rated
for cooling 3.5 kW
Rated capacity for heating P
rated
for heating 2.638 kW
Rated power input for cooling P
EER
1.346 kW
Rated power input for heating P
COP
1.147 kW
Ratedenergyefciencyratio EERd 2.6 -
Ratedcoefcientofperformance COPd 2.3 -
Power consumption in thermostat-off mode P
TO
N/A W
Power consumption in standby mode P
SB
0.5 W
Electricity consumption of double duct appliances
(indicate for cooling and heating separately)
DD:QDD N/A kWh/h
Electricity consumption of single duct appliances
(for cooling)
SD:QSD 1.346 kWh/h
Electricity consumption of single duct appliances
(for heating)
SD:QSD 1.147 kWh/h
Sound power level LWA 65 dB(A)
Global warming potential GWP 3 kgCO
2
eq.
Tones of CO
2
equivalent 0.000678 t
N/A - Not applicable.
Troubleshooting
If a condition listed below occurs, please check the following items before calling customer service.
Problem Possible Cause Solution
1. Unit does not start when
pressing on/off button
Water full indicator lamp blinks, and
water tank is full.
Dump the water out of the water
tank.
Room temperature is lower than the
setting temperature (Cooling mode).
Reset the temperature.
2. Not cool enough The doors or windows are not
closed.
Make sure all the windows and
doors are closed.
There are heat sources inside the
room.
Remove the heat sources if
possible.
Exhaust air hose is not connected
or blocked.
Connect or clean the exhaust air
hose.
Temperature setting is too high. Reset the temperature.
Air inlet is blocked. Clean the air inlet.
3. Noisy Thegroundisnotlevelornotat
enough.
Placetheunitonaat,level
ground if possible.
Thesoundcomesfromtheowing
of the refrigerant inside the air
conditioner.
It is normal.
4. The water full indicator lights
up frequently just 1 or 2 hours
after last time water drainage.
Water splash motor is damaged. Repair or replace.
5063022060242_MNL_IN_V04.indd 145063022060242_MNL_IN_V04.indd 14 12-12-2022 16:08:0612-12-2022 16:08:06