Model 670C Berkeley Nucleonics Corp. 52 of 96
This parameter is available in Advanced run mode only. It defines the behavior of the output when a
“Jump To” or a “Pattern Jump” event happens. If “Jump as soon as possible” is selected, the sequencer
jumps to the selected entry as soon as possible, without waiting for the completion of the repetitions of
the current waveform execution. It will jump always at the end of a period of the current waveform.
If “Jump when all repetitions have been executed” is selected, the sequencer jumps to the selected
entry after the completion of the current waveform repetitions.