which could occasionally exceed 120
o
F
. The variation in
outcoming temperature could be based on factors in
-
cluding but not limited to usage patterns and type of
installation. Test your water at the tap nearest to the wa-
ter heater.
WARNING: Hotter water increases the risk of scald in-
jury. Before changing the temperature setting, read the
instruction manual. Temperatures at which injury occurs
vary with the individual’s age and length of exposure.
The slower reaction times of children, elderly and phys-
ically or mentally impaired persons increases the
scalding hazard to them. It is recommended lower wa-
ter temperatures be used where these situations exist.
To lower water temperature use point-of-use tem-
perature limiting devices.
WARNING:
Flammable vapors may be drawn to this
water heater from other areas of the structure by air cur-
rents.
Do not store or use any flammable liquids in
the vicinity of this heater
.
WARNING: Water heater blankets may restrict air flow
to the heater and cause fire, asphyxiation, personal in-
jury or death.
W
ARNING:
Hydrogen gas can be produced in a hot
water system that has not been used for an extended
period–generally, two weeks or longer. To prevent pos-
sible injury under this situation, we recommend that a
hot water faucet be wide open for several minutes
before you use
ANY
electrical appliance that is connect
-
ed to the hot water system. If hydrogen is present, an
unusual sound – such as air escaping – will come from
the open faucet as the hot water begins to flow
.
Hydrogen gas is extremely flammable – there must
be no open flame near this open faucet.
TO THE INSTALLER:
Please attach these in-
structions next to the
water heater.
TO THE CONSUMER:
Read these and all
component instruc-
tions. Please keep for
future reference.
Waranty, registration card
& parts list included.
INSTALLATION, OPERATION
& MAINTENANCE INSTRUCTIONS
OIL-FIRED WATER HEATERS
72E • 73E • 190E • 241E • 361E • 541E
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause serious injury or
property damage. Refer to this manual. For assistance
or additional information, consult a qualified installer or
service agency.
WARNING: If the information in these instructions is not
followed exactly, fire or explosion may result and can
cause property damage, personal injury or death.
DO NOT INSTALL THE WATER HEATER ON COMBUSTI-
BLE FLOORING.
Install in accordance with all local
codes. In the absence of local codes, refer to NFPA 31
or ANSI Z21.10.1,
or contact Bock Water Heaters with
questions concerning proper flooring materials.
Minimum clearance to combustible construction is:
SIDES 6"; BACK 6"; FRONT 24". The installation of this
water heater must conform with local codes and ordi-
nances. In the absence of local codes, the installation
must comply with the National Fire Protection Associa-
tion (NFPA 31) Code.
WARNING: The recommended temperature for normal
residential use is 120
o
F. The dial on the aquastat does
not always reflect the outcoming water temperature,
Bock Water Heaters, Inc.
110 S. Dickinson St. • P.O. Box 8632 • Madison, WI 53708-8632
Phone: 608/257-2225 • Fax: 608/257-5304 • www.bockwaterheaters.com
Question and Answer IconNeed help?

Do you have a question about the Bock Water heaters 241E and is the answer not in the manual?

Summary

General Information and Safety

Installer and Consumer Guidance

Instructions for installers and consumers regarding documentation and reference.

Critical Safety Precautions

Essential warnings covering installation, operation, flammability, and scalding hazards.

Specifications and Dimensions

Burner Specifications

Details on burner models, nozzle sizes, and pressure ratings.

Unit Sizes and Capacities

Table listing model capacities, input, firing rates, and shipping weights.

Combustion and Ventilation Air

Air Supply Requirements

Guidelines for providing adequate combustion and ventilation air for the water heater.

Water Piping and Safety Valves

Instructions for water piping connections and T&P relief valve installation.

System Connections and Operation

Oil System and Water Softener

Recommendations for water softeners and detailed instructions for oil system connections.

Electrical Wiring and Startup Procedure

Guidance on electrical wiring and the initial process of putting the heater into operation.

Adjustment, Service, and Maintenance

Draft and Burner Adjustment

Procedures for setting draft, adjusting the burner, and checking CO2/O2 levels.

Troubleshooting and Preventative Care

Covers common service issues, cleaning, and checks for optimal performance.

Parts Identification

Tank Assembly Parts List

Illustrated list of components for the water heater tank assembly.

Parts and Warranty

Burner Components List

List of components for the burner assembly.

Limited Warranty Details

Details on warranty coverage, company and owner responsibilities, and exceptions.

Bock Water heaters 241E Specifications

General IconGeneral
BrandBock Water heaters
Model241E
CategoryWater Heater
LanguageEnglish

Related product manuals