Quick Start
7
Technical Support: 814-777-3890
© 2022 Bock Industries, Incorporated.
All Rights Reserved.
We recommend standard air tool oil be added directly into
the air hose connector on the Zephyr daily.
During depopulation, clean and add air tool oil after every
500 shots.
1. Daily Cleaning and Maintenance:
1.1 Remove air line from Zephyr.
1.2 Unscrew ADAPTER to expose BOLT.
1.3 Descend BOLT by grasping or shaking downward.
1.4 Clean and disinfect exposed BOLT and ADAPTER with
Lysol
® / Dettol®. Disinfectant wipes as available.
1.5 Reassemble ADAPTER and confirm BOLT moves freely
in ADAPTER. BOLT should be able to be shaken down.
Dried matter on the inside of the ADAPTER will block
BOLT during firing and may damage Zephyr.
1.6 Add 2 drops of air tool oil into the air hose
connector on the Zephyr.
1.7 Connect to air line and dry fire 5x to distribute the oil.
1.8 Disconnect from air line and turn SAFETY LEVER “up”
to engage safety.
1.9 Return Zephyr to case and store in a secure location.
Maintenance 1/2
EXL
Video Training