11
• Check the drum regularly on dirt or fiber residues;
clean the drum and the inside of the door also
with a soft, damp cloth.
• Dry the appliances thoroughly before taking in
operation again.
Cleaning the
Cleaning the Cleaning the
Cleaning the lint filter
lint filterlint filter
lint filter
CAUTION
CAUTIONCAUTION
CAUTION:
::
:
• Dirty filter affect the drying result. Check and
clean the filter regularly.
• The appliance must never be operated without
installed filter. Improper insertion of filter may af-
fect the performance and damage the appliance.
The lint filter catches all fibres which accumulate
during drying. Clean the filter before or after each
drying cycle.
• Remove the filter upwards.
• Open on the lint filter.
• Wipe off the lint by hand, if necessary use a damp
cloth or clean the filter under running water.
• Dry the filter thoroughly and replace if correctly.
Trou
TrouTrou
Troubleshooting
bleshootingbleshooting
bleshooting
Before you contact an
Before you contact anBefore you contact an
Before you contact an
authorized specialist
authorized specialistauthorized specialist
authorized specialist
Problem
ProblemProblem
Problem
Cause / Action
Cause / ActionCause / Action
Cause / Action
Appliance does
not work.
∙ Check the power supply. ∙ Is the
appliance switched on? ∙Is a pro-
gram selected? ∙ Consider the max-
imum loading.
The housing is
hot or there is a
smell of burning.
∙ Lint filter is blocked and must be
cleaned. ∙ Vent hose or ventilation
openings are blocked.
Unusual odours
and powerful
vibrations.
∙ The appliance must stand on a
solid base. ∙ Are the feet aligned?
Fabrics are
misshapen.
∙ Always follow the instructions on
the care label of your fabrics.
Error messages
Error messagesError messages
Error messages
With some malfunctions the appliance indicates the
following error codes to warn you:
E
E
E
E
r
r
r
r
ror code
ror code
ror code
ror code
Descript
Descript
Descript
Descript
i
i
i
i
on
on
on
on
Reason
ReasonReason
Reason
Action
ActionAction
Action
C
CC
Control
ontrol ontrol
ontrol
lamps
lamps lamps
lamps
flashing
flashingflashing
flashing
E1
E1
E1
E1
Over-
Temperature
Sensor is
short or PCB
fault
[Leicht] &
[Standard]
E4
E4
E4
E4
[Extra]
NOTE
NOTENOTE
NOTE:
::
:
If a problem still persists after following the steps
above, contact your distributor or an authorized tech-
nician.
Technical Data
Technical DataTechnical Data
Technical Data
Electrical conne
Electrical conneElectrical conne
Electrical connec
cc
ction
tiontion
tion………………..
………………..………………..
………………...
..
.…………………..
…………………..…………………..
…………………..
Connection voltage: …………......….220-240 V~ / 50 Hz
Connection power: …………..…………….……...2000 W
Dimension H x W x D / Weight…..…...………………..
Dimension H x W x D / Weight…..…...………………..Dimension H x W x D / Weight…..…...………………..
Dimension H x W x D / Weight…..…...………………..
Unit size: ………….....….……….…84.0 x 59.5 x 55.5 cm
Net weight: …………………………..……approx. 33.0 kg
The right to make technical and design modifications
in the course of continuous product development
remains reserved.
This appliance has been tested according to all rele-
vant current CE guidelines, such as electromagnetic
compatibility and low voltage directives, and has
been constructed in accordance with the latest safety
regulations.