20
Replacement of the demineralisation
cartridge
Always unplug the unit before removing the
water tank. Do not touch the water in the base
during operation!
Option A: replace the resin
Turn around the tank and open the turn-lock (18). The
demineralisation cartridge is attached to the inside of
the cap. Unscrew the cartridge turning it anti-clockwise
(19). Important: do not dispose of the tank cap!
Open the cartridge (20).
Throw the content into the waste (Attention! Thrown
out resin can make the floor slippery!) (21a).
Cut the bag open at the marked point (22a).
Insert the piece of styrofoam into the provided opening
(23).
Put the open bag over the cartridge and fasten it to the
cartridge right at the top using the rubber band (24).
Pour the replacement resin into the cartridge (25)
Remove the bag, rubber band and styrofoam piece
(26).
Close the cap (27).
Screw the cartridge on the water tank cap (28). Close
the tank cap well, place the tank on the lower part, and
insert the vapour outlet (29).
Soak the new granules for 24h before use! The resin
must soak up water to reach full performance!
Option B: replace the whole cartridge
Turn around the tank and open the turn-lock (18). The
demineralisation cartridge is attached to the inside of
the cap. Unscrew the cartridge turning it anti-clockwise
(19). Important: do not dispose of the tank cap!
Throw the whole cartridge into the waste (21b)
Unpack the new cartridge (22b)
Screw the cartridge on the water tank cap (28). Close
tank cap well, place the tank on the lower part and
insert vapour outlet (29).
23
Soak the new cartridge for 24h before use! The resin
must soak up water to reach full performance!
Cleaning/Maintenance
Always unplug the unit before removing the
water tank. Do not touch the water in the base
during operation!
Switch of the appliance and unplug it from the socket
before cleaning it (30).
Clean the water tank and the reservoir regularly once
a week. When operating with preheating every two
weeks (31).
Use decalcification agents found in stores everywhere
to remove deposits from the fogging chamber regularly
(32). Rinse out the decalcification agent thoroughly
with plenty of water.
Attention
Make sure that no water gets into the lower part of the
main body (33).
Clean the inner parts with a soft cloth. Do not use any
solvents or aggressive cleaning agents to clean the
appliance (34).
Only use the brush to clean the membrane. This should
be done once a week.
Change the water in the tank at least once a week.