Cleaning the Inlet Valve
Cleaning or servicing the inlet valve may be required if the unit has priming problems. Priming problems may be prevented by properly cleaning the sprayer
and following the Long-Term Storage steps.
1. Remove the sucon set. 2. Unscrew the inlet valve assembly (a) from the sprayer. Visually
inspect the inside and outside of the inlet valve assembly. Clean any
paint residue with the appropriate cleaning soluon.
3. Lubricate the O-ring on the inlet valve (b). Replace inlet valve as-
sembly by screwing it into the sprayer. Torque to 23-27  lbs.
If priming problems persist, you may need to replace the inlet
valve assembly. Call Customer Service to order new inlet valve
assembly.
4. Replace sucon set and hand-ghten.