6 720 644 942
Appliance details
3
2 Appliance details
2.1 520 HN specifications (Technical
data)
Approved in US/Canada
Capacity
520 HN: 4.36 GPM
Minimum input
520 HN: 30,735 Btu/hr
Maximum input
520 HN: 117 000 Btu/hr
Min. Output
520 HN: 23 906 Btu/hr
Maximum output
520 HN: 91 525 Btu/hr
Efficiency in %
Efficiency 80%
Gas Requirement
Gas connection - ¾” NPT
Inlet gas pressure under maximum operation:*
Propane: 10.5” - 14” water column
Natural Gas: 5.7” - 14” water column.
* To measure Gas Pressure, see Measuring Gas
Pressure, chapter 3.7.
Venting
Natural Draft
Vent diameter - 5" or 6"
Minimum height (feet) - 6’ with no elbows
Vertical termination through roof or into chimney.
Sidewall termination only with AQ4 power vent kit.
Water
Hot water connection - ½” NPT
Cold water connection - ½” NPT
Water valve material: Fiberglass reinforced polymide
(PA)
Minimum water flow to activate heater: 0.5 gallon/
minute (1.9 l/m)
Minimum recommended water pressure: 30 PSI
(2.07 bar)
Connections:
Bottom of heater
Temperature rises:
1)
45F rise @ 4.1 gpm
50F rise @ 3.7 gpm
55F rise @ 3.4 gpm
65F rise @ 2.8 gpm
77F rise @ 2.4 gpm
90F rise @ 2.0 gpm
Dimensions
Depth (in): 8.66” (220 mm)
Width (in): 16.73” (425 mm)
Height (in): 25.75” (655 mm)
Weight: 35 pounds (16 kg).
Gas types
Natural Gas
LP Gas
Safety devices
Flame failure device (ionization flame rod)
Pressure relief valve (Available as accessory)
Overheat prevention (temperature limiter).
Water protection
IP X4.
Accessories (Bosch part #)
Freeze prevention kit (7709003775)
2)
Pressure relief valve (FWL-2).
1) Depending on gas pressure and altitude.
2) The freeze prevention kit is designed to provide protec-
tion for the water heater down to approximately 5°F for
short term conditions only. It will not protect the appli-
ance in areas where the temperature is routinely
expected to be below freezing.
- The freeze prevention kit will not protect plumbing out-
side the appliance from freezing. Precautions should be
taken.