EasyManuals Logo

Bosch B4512 Quick Start Guide

Bosch B4512
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SLOT
SLOT 2
Open 3.7 - 5.0 VD
C
Normal 2.0 - 3.0 VDC
Short 0.0 - 1.3 VDC
ETHERNET
100
BASE-T
LINK
USB
COMMU
NICATION M
ODULE 1
C
OUTPUT
B
SDI2
Device Bu
s
R Y G B
ON-BOARD POINTS
1 COM 2
3 COM
4
5
COM
6
7 COM 8
1 k
End of Line Resistor
s
OUTPUT A
OUTPUT A
OUTPUT A
18 VAC
BATTERY
AUX
- 12V +
AUX PWR
COM
DR
Y
J
umper Under Cover
ʊ
Communication Devices
Quick Start Guide
B5512/B4512 Control Panel
1
= PC direct, connect using AutoIP (Wi-Fi off, wait 2 min)
2
= PC direct, connect using Male A to Male A USB cable
On-board Inputs and Outputs
SDI2 Specifi cations
Unshielded, 4 conductor, 22-12 gauge cable
Maximum cable length 1000’ single run, 7500’ system total
Allows a combination of home run, daisy chain and T-tapping wiring confi gurations
SDI2 Device Type Options
Device Type Part # Description ISRG #
Maximum #
of Devices
Address NotesB5512 B4512
Keypad B920 2-line, LCD 9.1.1
8* 8*
01...08
Similar device
types must use
different
addresses.
Different device
types may use
the same
address.
* Maximum of 8
keypads and 1
RF receiver per
system.
B930 5-line, ATM 9.1.2 01...08
I/O Expander B208 8-input 13.1 4 2 01...08
B308 8-output 11.1 5 3 01...08
RF Receiver
B810 Bosch RADION 14.1
1* 1*
1
B820 Inovonics 14.2 1
Power Supply B520 12V DC, 2A 6.3 4 2 01...04
B10 Enclosure
B11 Enclosure
Need more help?
For detailed instructions, refer to the Installation and
System Reference Guide chapter number (ISRG #5.2 )
included on the CD provided with the control panel.
Control Panel Mounting Locations
Attaching Mounting Clips
Technology
Location
ISRG
#
Terminal Description Specifi cation
18VAC
Transformer 18V AC 22VA Plug-in
Earth Ground Cold water pipe, or similar
+ BAT - Battery 12V DC 7Ah
NO C NC Output A Switched AUX, COM, or Dry
COM AUX Aux Power 12V DC, 800mA
R Y G B SDI2 Bus
Keypads, SDI2 devices, terminal
and Quickconnect in parallel
1 COM 2 Alarm Inputs 1k Ohm EOL
TMPR Tamper Optional tamper switch
B C Outputs B, C
Open collector, 50mA,
active low
RESET Reset Switch
Hold 5 seconds to enter or
exit service mode
Heartbeat
Slow =normal, Rapid=service
mode
MODULE 1 Plug-in Communication module options
Reporting
Text Messages
Remote RPS Programming
Local RPS Programming
iOS Remote Security App
Ethernet On-board 7.5
Cellular
B440
Plug-in
8.2
Telephone
B430
Plug-in
7
USB On-board 3.3.8
Transformer
2
1

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories

Related product manuals