Do you have a question about the Bosch B9512G-E and is the answer not in the manual?
Model | B9512G-E |
---|---|
Type | Control Panel |
Brand | Bosch |
Series | G Series |
Number of Zones | 8 |
Expandable Zones | Yes |
No. of Points | 599 |
Wireless Compatibility | Yes |
Communication | Ethernet, Cellular, PSTN |
Power Supply | 16.5V AC |
Operating Temperature | 0°C to +50°C |
Weight | 4.8 lbs (2.2 kg) |
Details UL, ULC, SIA, DoD, DoE, NIST, FCC, IC, and CE listings and approvals for compliance.
Covers critical safety guidelines for lightning, earth ground, and power handling during installation.
Provides information on document structure, notifications (Notice, Caution, Warning), copyright, and trademarks.
Guidance on obtaining additional product documentation from the Bosch website.
Explains how to find product manufacturing dates using the serial number and the Bosch website.
Details the control panel's physical parts and its operational capacities for users, doors, keypads, etc.
Covers SDI2 wiring, points, areas, digital communication, keypads, events, programming, firmware, access control, ground fault, dual auth, and recent closing.
Lists compatible accessories and their compliance with various UL standards for different applications.
Provides a comprehensive checklist for installing the enclosure, control panel, wiring, and completing the setup.
Instructions for mounting the enclosure, including removing knockouts and positioning the label.
Steps for positioning and securing the control panel onto the enclosure's back, including earth grounding.
Details installing and managing the 12 VDC battery for backup power, including status LEDs and maintenance.
Information on the optional B520 providing 12 VDC standby power for fire and burglar applications.
Details the B430 module for PSTN communication, including FCC registration, supervision, and installation.
Covers phone jack location, line monitoring, called party disconnect, and communication failure modes.
Details the built-in Ethernet port for network connection, including supervision, local programming, and diagnostic LEDs.
Information on using plug-in cellular modules for communication via a cellular network.
Information on installing and wiring the B426 module for IP connectivity, including address settings and supervision.
Covers the B450 interface for cellular modules, including address settings, supervision, and wiring.
Lists compatible receivers for IP communication and required software/firmware updates for compatibility.
Details keypad types, features, installation, wiring, address settings, supervision, and troubleshooting.
Instructions for connecting and operating keyswitches for arming and disarming areas, including wiring.
Information on RADION keyfobs and Inovonics pendant transmitters supported by the control panel.
Covers circuit protection, total available power, and specifications for on-board outputs like alarm and auxiliary power.
Details programmable outputs at terminals 6, 7, and 8 for various functions like alarm bells and smoke detector verification.
Information on enabling and using the USB port for powering connected devices.
Details the B308 module for eight off-board outputs, including address settings, supervision, and wiring.
Information on connecting ZONEX devices using the B600 module, including installation and wiring.
Details the D8129 module for eight relay outputs, including address settings and restrictions for fire applications.
Explains configuring sensor loops with single or dual EOL resistors for supervision and point type settings.
Details setting the debounce time for point response to alarms and exceptions.
Details the B208 module for eight off-board points, including address settings, supervision, and wiring.
Information on the B299 POPEX module for up to 100 POPIT devices, including address settings and wiring.
Covers B600 ZONEX module, D8125 expansion, and D8128D OctoPOPIT expander for off-board points.
Procedures for testing off-board points, handling extra point events, and managing missing point conditions.
Details the B810 wireless receiver for RADION devices, including address settings, supervision, and installation.
Information on the B820 module for connecting to Inovonics receivers, including address settings and wiring.
Details the B901 module for access control integration, including address settings, supervision, and wiring.
Information on the D9210C module for access door points and door strike connections.
Instructions for wiring access control modules to card readers, referencing reader-specific documentation.
Methods for programming the control panel using RPS, Installer Services Portal, or keypad menus.
Procedures for performing fire, intrusion, service, and invisible walk tests on system points for verification.
Identifies key components and connectors on the control panel board with cross-references to detailed information.
Diagrams illustrating power supply connections, including batteries, auxiliary power, and supervision modules.
Wiring diagrams for input points using D125B, D130, D129 modules, and EOL resistor configurations.
Wiring diagrams for SDI and ZONEX devices, including B600 module connections and device types.
Recommendations and diagrams for wiring SDI2 devices, including bus wiring topology and maximum cable lengths.
Specific wiring instructions for connecting 2-wire smoke detectors using the D125B module.
Details compatibility for burglar, bank safe/vault, and fire applications, including enclosure requirements and proximity alarms.
Lists components and their compatibility across various UL application standards, categorized by device type.
Calculations and requirements for standby battery capacity based on application, device load, and minimum standby times.
Guide to accessing the Installer Menu for programming system parameters like reporting, network, areas, and keypad settings.
Instructions for enrolling, replacing, removing, and diagnosing wireless points and repeaters via the keypad.
How to view diagnostics for wireless, network, cellular, IP camera, and cloud connections through the keypad.
Procedures for service bypassing points, viewing system versions, managing cloud connectivity, and controlling USB power.
Details control panel power supply, current requirements, power output specifications, and operating voltage.
Covers SDI, SDI2, Network, USB, environmental, and arming station specifications, plus wire gauge requirements.
Specifies point thresholds for EOL resistors and wire gauge requirements for terminals.
Provides address and switch settings for various modules like B208, B299, B308, D8128D, D8129, B901, B91x, D9210C, and keypads.
Details report formats, device numbers, communication trouble codes, special user IDs, and virtual point numbers for panel events.
Instructions for configuring AutoIP for control panel network connection via RPS or Installer Services Portal.