en Installation instructions
22
WARNING‒Risk of electric shock!
Incorrect installation is dangerous.
▶ Only a qualified electrician may route the socket or
replace a power cable while taking into considera-
tion the applicable regulations.
▶ Connect the appliance only to a correctly installed,
earthed socket.
▶ If the plug is no longer accessible following installa-
tion, an all-pole isolating unit with a contact clear-
ance of at least 3mm must be available on the in-
stallation side. Contact protection must be ensured
by the installation.
Electrically connecting an appliance without a
protective contact plug
Note:Only licensed specialists may connect the appli-
ance. Damage caused by incorrect connection is not
covered under the warranty.
An isolating switch must be integrated into the perman-
ent electrical installation according to the installation
regulations.
1.
Identify the phase and neutral conductors in the
socket.
The appliance may be damaged if it is not connec-
ted correctly.
2.
See the rating plate for the voltage.
3.
Connect the wires of the mains power cable accord-
ing to the colour coding:
‒ Green/yellow = Protective conductor
‒ Blue = Neutral conductor
‒ Brown = Phase (external conductor)
16.4 Installation in a wall unit
Observe the installation dimensions and the safety
clearances in an upper cabinet.
Only install 20l appliances in a wall unit.
16.5 Installing in a tall cupboard
Observe the installation dimensions and the safety
clearances in a tall unit.
16.6 Preparing the 20l appliance
1.
For a cabinet niche of 380
+2
mm in height, secure
the feet to the bottom of the microwave.
‒ Secure the spacer to the mounting bracket.
2.
Route the connecting cable along the back of the
appliance so that it does not become hot, kinked or
trapped.