6 720 646 812
Appliance details
5
2 Appliance details
2.1 Features
Parts
Key Pad interface control
High power pre-mix compact burner with low NOx
emissions
Modulating Gas Valve with constant gas:air ratio
control
Modulating water valve for improved comfort and
temperature control.
High quality materials for long working life
Copper heat exchanger
High efficiency Ceramat Burner
Compact space saver: mounts on a wall with a
supplied bracket.
Features
Easily removable one-piece cover
On/Off and Temperature control switches
Reset button
Program button (Selectable temperature default)
Failure codes for easy diagnostics and repair
Real-time diagnostics for troubleshooting/informa-
tional purposes
Built in freeze prevention.
Note: The freeze prevention kit is designed to provide
protection for the water heater down to approximately
5°F for short term conditions only. It will not protect the
appliance in areas where the temperature is routinely
expected to be below freezing.
- The freeze prevention kit will not protect plumbing out-
side the appliance from freezing. Precautions should be
taken.
Accessories (Bosch part #)
Optional wireless remote control to operate with the
appliance (TSTAT2)
Cascading kit (77090003962)
Outdoor kit (BTOK)
External water filter (part # 8 703 305 356)
Concentric termination kit (196016)
Exhaust/Intake bird screen (L2594)
Condensate drain tee (196061) [included with Con-
centric termination kit]
Pipe Cover (PTPCES)
High temperature kit (7736500074)
Recess box kit (7736500043)
Pressure relief valve (FWL-2).
2.2 Specifications (Technical data)
Approved in US/Canada
Capacity
Maximum flow rate: 7.15 GPM (27 l/min) at a 45°F
(25°C) rise.
Maximum output
157,700 Btu/h (46.2 kW)
Maximum input
175,000 Btu/h (51.2 kW)
Efficiency in %
Thermal efficiency > 92%
Minimum Input
19,900 Btu/h (5.8 kW)
Temperature Control
Selection range: 100°F (38°C) - 140°F (60°C)
Default temperature: 122°F (50°C)
Stability: +/- 2°F (+/- 1°C)
Gas Requirement
Gas connection (inches) - ¾”
Inlet gas pressure under operation (with a high hot
water flow rate)*
Propane: 8” - 13” water column
Natural Gas: 3.5” - 10.5” water column.
* To measure Gas Pressure, see Measuring Gas
Pressure, chapter 3.14, page 35.
Water
Hot water connection (inches) - ¾”
Cold water connection (inches) - ¾”
Water valve material: Polymer (PPS) (Polypropylene
Sulfid)
Minimum water flow: 0.5 gallon/minute (1.9 l/m)
Note: Activation varies with inlet water temperatures
from 0.5 - 1.6 gallon/minute (1.9 - 6.1 l/m).
Minimum recommended water pressure: 30 PSI
(2.07 bar)
Minimum well pressure 40 psi, see page 29.
Connections:
Bottom of heater
Combustion
NOx 14 Ng/J
(Nanograms of NOx (calculated as NO
2
) per
Joule of heat output).
i
BOSCH is constantly improving its
products, therefore specifications are
subject to change without prior notice.