EasyManua.ls Logo

Bosch C 950 - Specifications (Technical Data)

Bosch C 950
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appliance details | 7
6 720 805 440 (2014/11)Greentherm
3.2 Specifications (Technical data)
Approved in US/Canada
Safety devices
Flame failure device (ionization flame rod sensor)
Overheat prevention (temperature limiter)
Inlet temperature sensor
Outlet temperature sensor
Back flow temperature sensor
Exhaust gas temperature sensor
Technical characteristics Units C950 ES C1050 ES
Capacity
Maximum flow rate at a 25 °F (13.9 °C) rise GPM (l/min) 13.1 (49.7) 14.9 (56.5)
Maximum flow rate at a 35 °F (19.4 °C) rise GPM (l/min) 9.4 (35.5) 10.7 (40.4)
Maximum flow rate at a 45 °F (25 °C) rise GPM (l/min) 7.3 (27.6) 8.3 (31.4)
Maximum flow rate at a 55 °F (30.6 °C) rise GPM (l/min) 6.0 (22.6) 6.8 (25.7)
Maximum flow rate at a 75 °F (41.7 °C) rise GPM (l/min) 4.4 (16.5) 5.0 (18.8)
Maximum flow rate at a 90 °F (50 °C) rise GPM (l/min) 3.6 (13.8) 4.2 (15.7)
Maximum output BTU/hr (kW) 160,500 (47) 184,500 (54)
Maximum input BTU/hr (kW) 175,000 (51.2) 199,000 (58.3)
Thermal efficiency (Efficiency in %) % > 94%
Minimum Input BTU/hr (kW) 19,900 (5.8)
Temperature Control
Selection range °F ( °C) 100 - 140 (38 - 60)
Default temperature °F ( °C) 122 (50)
Stability °F ( °C) 2 ( 1)
Gas Requirement
Gas connection inches ¾"
Peak load inlet gas pressure
1)
1) To measure Gas Pressure, see Measuring Gas Pressure, chapter 4.14, page 36.
Propane water column 8” - 13”
Natural Gas water column 3.5” - 10.5”
Water
Hot water connection inches ¾"
Cold water connection inches ¾"
Minimum water flow
2)
2) Activation varies with inlet water temperatures from 0.5 - 1.6 gallon/minute (1.9 - 6.1 l/m).
GPM (l/min) 0.5 (1.9)
Minimum recommended water pressure PSI (bar) 30 (2.07)
Minimum well pressure PSI 40
Water valve material Polymer (PPS) (Polypropylene Sulfide)
Connections: Bottom of heater
Combustion
CO level ppm 290 (measured)
CO
2
level (set from factory) % see table 48
Dimensions
Depth inches (mm) 11 ¼ (286)
Width inches (mm) 17
7
/
8
(452)
Height inches (mm) 30½ (775)
Weight pounds (kg) 74 (33.5)
Nominal V AC 120
Frequency Hz 60
Amperage
Idle mA 40
Operation A 2.5
Noise db (A) 45 - 65
Water protection
3)
3) Protection against water drops.
IP X4D
Table 3
If appliance is installed at elevations above 2000ft, refer
to chapter 4.3.8 Fan speed adjustment.