Summary

Explanation of Symbols and Safety Instructions

Explanation of Symbols

Defines signal words like DANGER, WARNING, CAUTION, and NOTICE for risk communication.

General Safety Instructions

Outlines essential safety guidelines for the heating system user and proper appliance usage.

Product Information

Declaration of Conformity

Confirms compliance with EU legislation and CE marking requirements for the product.

Appliance Types

Lists the specific models of Condens 5000W boilers covered by this manual.

Commissioning

Overview of Components

Identifies and describes the main components of the wall-mounted gas condensing boiler.

Opening the Gas Tap

Step-by-step instructions for safely opening the gas supply tap.

Opening Service Valves

Instructions for opening the appliance's service valves for maintenance or operation.

Operating the Appliance

Control Panel and Display

Details the functions of the control panel buttons and the information shown on the display.

Information Menu

Guide to accessing and reading operational status and fault information from the boiler.

Setup Menu

Instructions for configuring appliance settings like temperature and pump speed.

Anti-Freeze Protection

Details how to protect the system from freezing during cold weather.

Key Lock

Explains how to activate and deactivate the control panel's key lock function.

Shutdown

Standard Shutdown

Procedure for safely performing a routine shutdown of the boiler.

Shutting Down When There Is a Risk of Frost

Specific steps for shutting down the appliance to prevent frost damage.

Inspection and Maintenance

Refilling the Heating System

Guidance on the process of refilling the heating system with water.

Cleaning the Casing

Instructions for cleaning the exterior of the boiler unit.

Display Rendition

Display Codes

Explains fault and operating codes displayed by the boiler.

A Fault Has Occurred But No Fault Code Is Displayed

Troubleshooting steps when the boiler malfunctions without a displayed code.

Environmental Protection;Disposal

Summary

Explanation of Symbols and Safety Instructions

Explanation of Symbols

Defines signal words like DANGER, WARNING, CAUTION, and NOTICE for risk communication.

General Safety Instructions

Outlines essential safety guidelines for the heating system user and proper appliance usage.

Product Information

Declaration of Conformity

Confirms compliance with EU legislation and CE marking requirements for the product.

Appliance Types

Lists the specific models of Condens 5000W boilers covered by this manual.

Commissioning

Overview of Components

Identifies and describes the main components of the wall-mounted gas condensing boiler.

Opening the Gas Tap

Step-by-step instructions for safely opening the gas supply tap.

Opening Service Valves

Instructions for opening the appliance's service valves for maintenance or operation.

Operating the Appliance

Control Panel and Display

Details the functions of the control panel buttons and the information shown on the display.

Information Menu

Guide to accessing and reading operational status and fault information from the boiler.

Setup Menu

Instructions for configuring appliance settings like temperature and pump speed.

Anti-Freeze Protection

Details how to protect the system from freezing during cold weather.

Key Lock

Explains how to activate and deactivate the control panel's key lock function.

Shutdown

Standard Shutdown

Procedure for safely performing a routine shutdown of the boiler.

Shutting Down When There Is a Risk of Frost

Specific steps for shutting down the appliance to prevent frost damage.

Inspection and Maintenance

Refilling the Heating System

Guidance on the process of refilling the heating system with water.

Cleaning the Casing

Instructions for cleaning the exterior of the boiler unit.

Display Rendition

Display Codes

Explains fault and operating codes displayed by the boiler.

A Fault Has Occurred But No Fault Code Is Displayed

Troubleshooting steps when the boiler malfunctions without a displayed code.

Environmental Protection;Disposal

Overview

This document provides operating instructions for the Bosch Condens 5000W series of wall-mounted gas condensing boilers, specifically models ZBR 70-3 and ZBR 100-3. It covers essential information for users to safely and efficiently operate and maintain their heating system.

Function Description

The Bosch Condens 5000W is a wall-mounted gas condensing boiler designed for heating boiler water and domestic hot water (DHW). It utilizes gas combustion to generate heat, and its condensing technology allows for higher efficiency by recovering heat from the flue gases. The boiler is equipped with a control panel that serves as the primary interface for users to monitor and adjust its operation. It can operate in various modes, including central heating and DHW production, which can be controlled independently. The system incorporates anti-freeze protection to prevent damage during cold seasons by ensuring continuous water flow through the heating system. In case of operational issues, the boiler is designed to display fault codes, providing users with information to diagnose and address problems.

Usage Features

The boiler's operation is managed through a user-friendly control panel, which includes an ON/OFF switch, a "Reset" key, an "Emissions test" key, a "Help" key, a "Menu" key, "Down" and "Up" arrow keys, and a diagnostic plug.

Commissioning: Before operation, users need to ensure the gas tap and service valves are open. The boiler is switched on using the ON/OFF switch. Water pressure can be checked directly on the display, and the heating system should be topped up if the pressure is too low (typically between 1.0 and 2.0 bar). The maximum boiler temperature can be set in the setup menu, allowing users to tailor the heating output to their specific needs (e.g., 40 °C for underfloor heating, 75-85 °C for radiators, 85-90 °C for convectors).

Operating the Appliance: The control panel allows access to two main menus: the information menu and the setup menu.

  • Information Menu: This menu provides real-time data on the boiler's status, such as actual ionisation current, actual burner output, actual pump speed, maximum boiler temperature setting, current operating pressure, and actual boiler temperature. It also displays service codes if the boiler requires attention.
  • Setup Menu: This menu allows users to modify various settings. Users can enable or disable heating mode, set the maximum boiler temperature, adjust the maximum output of the heating system, and change the minimum pump speed. The pump overrun time can also be set, which is particularly useful for anti-freeze protection.

Anti-Freeze Protection: To prevent freezing, users should ensure all radiator valves are open and set the pump overrun time to 24 hours in the setup menu. If the boiler is switched off, specific shutdown procedures for frost risk should be followed, which may involve draining the entire heating system.

Key Lock: The setup menu can be locked to prevent unauthorized changes to settings. This feature is activated and deactivated by simultaneously pressing the "Down" and "Up" arrow keys for 5 seconds. While locked, the information menu remains accessible.

Shutdown: For a standard shutdown, the ON/OFF switch should be set to "0," and the gas isolator under the boiler should be closed. In situations with a risk of frost, additional steps, such as setting the pump overrun time or draining the heating system, are required.

Maintenance Features

Regular inspection and maintenance are crucial for the safe and efficient operation of the Bosch Condens 5000W boiler.

Inspection and Maintenance: It is recommended that the heating system be inspected and serviced annually by a certified installer. This includes cleaning the heat source at least every two years. Users are encouraged to enter into an annual inspection and maintenance contract with an approved contractor.

Refilling the Heating System: The manual advises users to consult their installer for instructions on refilling the heating system, as the process may vary depending on water quality.

Cleaning the Casing: The boiler casing should only be cleaned with a damp cloth and, if necessary, a mild detergent.

Display Rendition and Fault Codes: The boiler provides detailed information through its display, including operating codes and fault codes.

  • Operating Codes: These codes indicate the current status of the boiler (e.g., heating mode, DHW mode, waiting, standby).
  • Fault Codes: In case of a fault, the boiler displays a fault code, often accompanied by an illuminated indicator. Users can access these codes via the information menu to understand the issue. The manual provides a table of common fault codes and their corresponding corrective measures, such as checking radiator valves, bleeding radiators/heating system, checking water pressure, or resetting the boiler.
  • Resetting Faults: For blocking faults, the boiler can often be restarted by holding down the "Reset" key until "rE" appears on the display. If a fault persists or if the boiler is not operating as expected without a displayed fault code, users are advised to contact an installer, providing the appliance type and serial number (found on the right-hand side of the boiler).

Safety Instructions: The manual emphasizes several safety instructions, including precautions for gas leaks, flue gas poisoning, and carbon monoxide. It stresses the importance of having all work carried out by an approved contractor, never modifying any parts of the heating system, and ensuring adequate ventilation for open flue operation. Environmental protection and proper disposal of the appliance and its packaging are also highlighted.

Bosch CONDENS 5000W Specifications

General IconGeneral
EfficiencyUp to 98%
Fuel TypeNatural Gas or LPG
InstallationWall-mounted
TypeGas Condensing Boiler
NOx EmissionsClass 5
Warranty2 years
Flue OptionsConcentric or Twin Flue