Divar | Operation Manual | Using the menu EN | 19
Bosch Security Systems
English
>> AUTHENTICITY CHECK
(access may require password)
This check verifies that video images and associated data have not been
modified.
Select the period within which the authenticity check runs. The default
values are the same as the earliest and latest available recording times.
Press the escape key to cancel the check.
During the check all other front panel keys are disabled.
If the result is Not OK, the date and time of the tampered video is displayed.
TIME/DATE >
Select a time zone from the list.
Fill in the actual time and date.
Select either a 12-hour or a 24-hour clock format.
Select from three date formats which show either the month (MM), the
day (DD) or the year (YYYY) first.
•Set Daylight Saving to Ye s to enable it. Fill in the day, month and time of
both change-overs and the offset if it differs from the information
associated with your time zone.
>> SYNCHRONIZE
•Use the Synchronize function to set the time of the unit from the time of
the network. (Synchronize only works if the Divar time is within 7½
minutes of the server time.) Fill in the IP address of the network time
server. If a time server is not present on the same subnet, the Divar
searches for a suitable time server outside its own network. Make sure
the Divar gateway is set correctly to find the time server. Ensure that
firewalls do not block NTP traffic via port 123.
The time and date of all other connected units are automatically
synchronized every hour from the time and date of the unit with DVR
ID 1.
MAIN MENU
DISK MANAGER
AUTHENTICITY CHECK
BEGIN TIME 2002-03-14 13:00:17
END TIME 2002-03-14 13:00:17
START CHECK >
PROGRESS 85%
RESULT NOT OK
DISK CONTENTS
EARLIEST TIME 2002-03-14 13:00:17
LATEST TIME 2002-03-14 13:00:17
MAIN MENU
TIME/DATE
TIME ZONE GMT +01:00 WEST-EUROPE
TIME FORMAT 24 HOUR
TIME 14:00:17
DATE FORMAT YYYY-MM-DD
DATE 2002-06-19
SYNCHRONIZE >
DAYLIGHT SAVING YES
START DATE/TIME LAST SUN MAR 02:00
END DATE/TIME LAST SUN SEP 03:00
OFFSET 01:00