English | 171 609 929 K06 12.6.06
Technical Data
Assembly
Inserting/Replacing
the Battery
Use only alkali-manganese batteries.
When the symbol appears in the
display 6, the battery must be replaced.
Carefully remove the battery lid 1 with
the battery holder out of the measuring
tool. Pay attention that neither the con-
nection cables of the battery nor the
battery lid are damaged. Excessive
damage on the supporting surface of
the battery lid 1 can lead to faulty
measurements.
Digital level DNM 60 L
PROFESSIONAL
Article number 3 601 K14 000
Length 600 mm
Weight accord-
ing to EPTA-Pro-
cedure 01/2003
0.7 kg
Digital level DNM 120 L
PROFESSIONAL
Article number 3 601 K14 100
Length 1200 mm
Weight accord-
ing to EPTA-Pro-
cedure 01/2003
1.3 kg
DNM 60 L/DNM 120 L
Measuring range 0–36 (4 x 9)
Measuring
accuracy
–0°/90°
1–8
±0.05°
± 0.2°
Levelling
accuracy of the
spirit level
±0.057°
(± 1 mm/m)
Operating
temperature 5 °C ... +50 °C
Storage
temperature
20 °C ... +85 °C
Battery 1 x 9 V 6LR 61
Operating life
time, approx.
200 h
Please observe the article number on the
type plate of your measuring tool. The trade
names of the individual measuring tools
may vary.
OBJ_BUCH-17-004.book Page 17 Monday, June 12, 2006 11:10 A
M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch DNM 120 L and is the answer not in the manual?

Bosch DNM 120 L Specifications

General IconGeneral
BrandBosch
ModelDNM 120 L
CategoryLaser Level
LanguageEnglish

Related product manuals