EasyManua.ls Logo

Bosch GIS 1000 C Professional - Troubleshooting - Causes and Corrective Measures

Bosch GIS 1000 C Professional
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 | English
1 609 92A 3FX | (22.9.16) Bosch Power Tools
Light Duration:
In the “Light Duration” menu you can choose the time in-
terval after which the brightness of the display lighting will
reduce if no button is pressed on the measuring tool. You
can also illuminate the display permanently by selecting
the “Always” setting. The shorter the light duration, the
more energy you can save
Delete All Images:
In the “Delete All Images” menu you can delete all files in
the internal memory at once. Press the right-hand arrow
button 11 for “more ...” to enter the submenu. Then press
either the left-hand function button 17 under the tick sym-
bol to delete all files, or the right-hand function button 10
under the cross symbol to cancel the operation.
Tool Information:
Open the “Tool Information” submenu for information
about the measuring tool. There you will find the serial
number of the measuring tool and the installed software
version.
Troubleshooting Causes and Corrective Measures
Definitions
Infrared heat radiation
Infrared heat radiation is electromagnetic radiation emitted
by every body. The amount of radiation depends on the tem-
perature and the emissivity degree of the body.
Emissivity Degree
The emissivity degree of an object depends on the material
and the structure of its surface. It states how much infrared
heat radiation the object emits compared to an ideal heat
emitter (black body, emissivity degree = 1).
Error Cause Corrective Measure
Measuring tool cannot be switched on.
Battery pack or batteries
empty
Charge the battery pack or change the batteries.
Battery too warm or too cold Allow the battery to reach the correct temperature or
change it.
Measuring tool too warm or
too cold
Allow the measuring tool to reach the correct temper-
ature.
Image memory defective Format the internal memory by deleting all images
(see “Delete All Images”, page 16). If the problem
persists, send the measuring tool to an authorised
Bosch after-sales service agent.
Image memory full If required, transfer the images to another storage
medium (e.g. computer or notebook). Then delete
the images in the internal memory.
Measuring tool is defective. Send the measuring tool to an authorised Bosch
after-sales service agent.
Function indicator t for contact tempera-
ture measurement does not appear on the
display.
Connection 25 for thermo-
couple defective
Send the measuring tool to an authorised Bosch
after-sales service agent.
Measuring tool cannot be connected to a
computer.
Measuring tool not recog-
nised by computer.
Check whether the driver on your computer is up to
date. It may be necessary to have a newer operating
system version on your computer.
Micro USB connection or mi-
cro USB cable defective
Check whether the measuring tool can be connected
to a different computer. If not, send the measuring
tool to an authorised Bosch after-sales service agent.
Humidity and ambient tem-
perature sensor 5 defective
The other functions of the measuring tool can still be
used.
Send the measuring tool to an authorised Bosch
after-sales service agent.
OBJ_BUCH-2452-005.book Page 16 Thursday, September 22, 2016 7:55 PM