English | 19
Bosch Power Tools 1 609 92A 3MW | (21.11.16)
– Measure the distance 10 times in succession.
The deviation of the individual measurements from
the average value must not exceed ±4 mm over the
entire measuring section in favourable conditions.
Record the measurements in order to be able to com-
pare the accuracy at a later date.
Troubleshooting – Causes and Corrective
Measures
Cause Corrective Measure
Temperature warning indicator (g) flashing;
measurement not possible
The measuring tool is out-
side the operating tem-
perature range of –10 °C
to +45 °C.
Wait until the measuring
tool has reached the op-
erating temperature
“Error” indication in the display
The target surface re-
flects too intensely (e.g.
a mirror) or insufficiently
(e.g. black fabric), or the
ambient light is too
bright.
Work with the laser target
plate 9 (accessory)
OBJ_BUCH-3062-001.book Page 19 Monday, November 21, 2016 4:09 PM