6 720 817 281 (2017/05)Greentherm 9800 SEO 160/199 | SECO 199
Troubleshooting | 37
Fig. 32 199kBTU appliance gas conversion kit
Fig. 33 160kBTU appliance gas conversion kit
▶Tighten the four screws.
▶ Open the gas supply valve.
▶ Place the front cover.
▶ Turn On the appliance power.
▶ Install temporally the CO
2
analyzer next to the appliance for
the following adjustments.
▶ Access service mode by pressing and hold down at the
same time, , and for 3 seconds.
Display with indication “P2”.
▶ Press buttons or until the display shows “P7”.
▶Press .
▶ Press buttons or and select the gas type
according to table 19.
▶ Update “TYPE OF GAS” in the rating plate of the appliance
using the label provided with the gas conversion kit.
▶ After changing the type of gas, proceed with the adjusting
maximum flow (P1) and minimum flow (P2) described in
section 10.11 Adjusting Gas/Air flow.
Gas type Display
Natural gas 20
Propane 31
Table 19