6 720 817 281 (2017/05)Greentherm 9800 SEO 160/199 | SECO 199
Problem solving | 41
E8 Error during ionization test. Electronic control unit
internal error.
Replace electronic control unit.
1)
E9 Thermal fuse [13] broken. Replace thermal fuse.
1)
EA Ignition failure. Check gas inlet pressure ( section 6.6).
1)
Perform gas and air tuning ( section 10.11).
1)
EC Flame lost during operation. Check gas inlet pressure ( section 6.6).
1)
Perform gas and air tuning ( section 10.11).
1)
EE Gas valve modulation solenoid [7] disconnected. Check gas valve wire connection.
1)
If the problem persists:
Replace the gas valve and/or wire connections and/
or electronic control unit. For gas valve replacement
perform gas and air tuning ( section 10.11).
1)
EF Wrong gas connected (LP instead of NG) for
current appliance configuration.
Check gas type ( section 3.3).
1)
F2 Electronic control unit internal error. Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F3 Electronic control unit internal error. Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F7 Electronic control unit internal error. Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F8 Electronic control unit internal error. Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F9 Gas valve driver internal fault. Check gas valve wire connections.
1)
If the problem persists:
Replace the wire connections and/or electronic
control unit.
1)
FA Gas leakage in the gas path (gas valve or gas
manifold shut-off valves).
Replace the gas valve and/or gas manifold.
1)
After gas valve and/or gas manifold replacement
perform gas and air tuning ( section 10.11).
1)
Display shows
SOLAR but without
existence of solar
thermal system.
Power demand lower than appliance minimum
output power.
Increase hot water flow.
increase setpoint temperature.
Display shows
SOLAR and water
temperature low.
Display Description Solution