12
Installation
6 720 608 992 (2018/01)
4.7 Gas connection
Gas regulator
The appliance is supplied with a gas pressure regulator that
must be installed on the heater before attaching the gas supply
line (see Fig. 6).
Use sealing tape to assure the complete tightness of the
installation.
Fig. 6 Gas regulator
4.8 Testing
Turn on the gas and water cocks and check all connections
for leaks. If all connections are sound then follow
procedures set out in Section 6 for adjustment of Gas
Pressures.
DANGER:
If local regulations are not followed, a fire or
explosion could result causing property
damage, personal injury, or loss of life.
Size gas supply as per AS5601.
Incorrect gas pipe sizing will not be covered by
the warranty.
6720608992-02.1JS